Daikin heat pump error codes

Daikin · A major brand in the UK. 343 codes across 9 product families, each taken from the manufacturer’s manuals. Daikin technical support ↗

Find a Daikin engineer →343 codes · reviewed 23 September 2026

Filter by product family

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

343 codes

CodeMeaningStops?Homeowner check?
7H
Flow abnormality
Not statedYes
7H-01
Water flow problem
YesYes
7H-04
Water flow problem during domestic hot water production
YesYes
7H-05
Water flow problem during heating/sampling
YesYes
7H-06
Water flow problem during cooling/defrost
YesYes
7H-07
Water flow problem. Pump deblocking active
NoYes
7H-08
Pump abnormality during operation (pump feedback)
NoYes
7H-09
Abnormal flow during emitter defrost
YesYes
7H-10
Abnormal flow during tank defrost
YesYes
7H-11
Flow abnormality during 4-way valve in cooling
YesYes
7H-12
Main zone pump blocked abnormality
PartlyYes
7H-13
Main zone pump electrical fault abnormality
PartlyYes
7H-14
Add. zone pump communication error
NoYes
7H-15
Add. zone pump blocked abnormality
PartlyYes
7H-16
Add. zone pump electrical fault abnormality
PartlyYes
7H-17
Main zone pump communication error
NoYes
7H-18
Water flow requirement problem at space cooling request
Not statedYes
7H-19
Water flow requirement problem at tank heat-up request
Not statedYes
7H-20
Water flow requirement problem on emitter hydraulic circuit
Not statedYes
7H-21
Water flow requirement problem on tank hydraulic circuit
Not statedYes
7H-22
Water flow requirement problem at space heating request or during Water pipe freeze prevention
Not statedYes
7H-23
Main zone pump communication error
YesYes
7H-24
Add. zone pump communication error
YesYes
8C-03
Undercooling of the space cooling water circuit
PartlyYes
8C-04
Undercooling of the main zone water circuit (e.g. stuck or broken mixing valve)
PartlyYes
8F-00
Abnormal increase outlet water temperature (DHW)
YesYes
8H
Outlet water temperature too high
Not statedYes
8H-00
Abnormal increase outlet water temperature
YesYes
8H-01
Overheating mixed water circuit
NoYes
8H-02
Overheating mixed water circuit (thermostat)
YesYes
8H-03
Overheating water circuit (thermostat)
PartlyYes
8H-08
Overheating water circuit
YesYes
8H-09
Backup heater stuck detection ongoing
YesYes
8H-10
Overheating mixed water safety thermostat (mixing kit)
PartlyYes
8H-11
Overheating/undercooling mixed water circuit (mixing kit)
PartlyYes
80
Inlet water temperature thermistor abnormality
Not statedYes
80-00
Returning water temperature sensor problem
YesYes
80-01
Returning water temperature sensor problem
YesYes
80-03
Entering water temperature thermistor main zone abnormality
NoYes
80-04
Entering water temperature thermistor add. zone abnormality
NoYes
81
Outlet water temperature thermistor abnormality
Not statedYes
81-00
Leaving water temperature sensor problem
YesYes
81-01
Mixed water thermistor abnormality
NoYes
81-04
Leaving water temperature sensor not properly mounted
Not statedYes
81-05
Loose hanging tank thermistor
YesYes
81-06
Entering water temperature thermistor abnormality (indoor unit)
YesYes
81-07
Exit water temperature thermistor after tank valve abnormality
YesYes
81-10
Mixed water thermistor abnormality (mixing kit)
PartlyYes
89
Water heat exchanger freeze-up abnormality
Not statedYes
89-01
Heat exchanger freeze-up protection activated during defrost (error)
YesYes
89-02
Heat exchanger freeze-up protection activated during heating / DHW operation. (warning)
Varies by modelYes
89-03
Heat exchanger freeze-up protection activated during defrost (warning)
Varies by modelYes
89-04
Interruption defrost during tank defrost
YesYes
89-05
Heat exchanger freeze-up protection activated during cooling operation. (error)
YesYes
89-06
Heat exchanger freeze-up protection activated during cooling operation. (warning)
NoYes
89-09
Heat exchanger freeze-up protection activated during 4-way valve in cooling
YesYes
89-10
Heat exchanger freeze-up protection activated during 4-way valve in cooling
YesYes
89-11
Heat exchanger freeze-up protection activated during defrost operation
YesYes
A0-02
Indoor unit gas sensor detection
YesYes
A1
PC board defect, E2 PROM defect
Not statedYes
A1-00
Zero cross detection problem
YesYes
A1-01
EEPROM reading error
YesYes
A5
Freeze-up protection or High pressure control
Not statedYes
A5-00
OU: High pressure peak cut / freeze protection problem
YesYes
A6
Pump error
Not statedYes
A9
Malfunction of moving part of electronic expansion valve (Y1E)
Not statedYes
AA
Back-up heater thermal protector is open
Not statedYes
AA-00
Back up heater safety error
YesYes
AA-01
Backup heater overheated or BUH power cable not connected
YesYes
AA-02
External backup heater overheated
YesYes
AA-07
Diverter valve is blocked or incorrect valve type is selected
YesYes
AA-08
Mixing valve is blocked or incorrect valve type is selected
YesYes
AA-09
Diverter valve is broken or incorrect valve type is selected
YesYes
AA-10
Mixing valve is broken or incorrect valve type is selected
YesYes
AA-11
Tank valve is blocked or incorrect valve type is selected
YesYes
AA-12
Bypass valve is blocked or incorrect valve type is selected
YesYes
AA-13
Tank valve is broken or incorrect valve type is selected
YesYes
AA-14
Bypass valve is broken or incorrect valve type is selected
YesYes
AC
Booster heater thermal protector is open
Not statedYes
AC-00
Booster heater overheated
NoYes
AE
Water Circuit Error
Not statedYes
AH-00
Tank disinfection function not completed correctly
NoYes
AJ
Malfunction of capacity setting
Not statedYes
AJ-03
Too long DHW heat-up time required
NoYes
C0
Flow switch abnormality
Not statedYes
C0-00
Flow sensor malfunction
YesYes
C0-01
Flow switch malfunction
YesYes
C0-02
Flow switch malfunction
YesYes
C0-14
Indoor gas sensor has a malfunction
YesYes
C0-15
Indoor gas sensor is disconnected
YesYes
C1
Failure of transmission (between indoor unit PC board and fan PC board)
Not statedYes
C1-10
ACS communication malfunction
Not statedYes
C1-11
ACS communication malfunction
Not statedYes
C4
Malfunction of thermistor (R3T) for R-410A liquid/indoor unit (loose connection, disconnection, short circuit, failure)
Not statedYes
C4-00
Heat exchanger temperature sensor problem
YesYes
C5
Malfunction of thermistor (R2T) for tank thermistor (loose connection, disconnection, short circuit, failure)
Not statedYes
C5-00
Heat exchanger thermistor abnormality
YesYes
C8-01
Current sensor abnormality
Not statedYes
C9
Malfunction of thermistor (R4T) for return water thermistor (loose connection, disconnection, short circuit, failure)
Not statedYes
CA
Malfunction of thermistor (R5T) for leaving water temperature (loose connection, disconnection, short circuit, failure)
Not statedYes
CJ
Malfunction of thermostat sensor in remote control
Not statedYes
CJ-02
Room temperature sensor problem
NoYes
E0-06
Outdoor unit leakage detection error
YesYes
E1
PC board defect
Not statedYes
E1-00
OU: PCB defect
YesYes
E2-00
Leakage current detection error
YesYes
E2-01
Leakage current detection error
YesYes
E2-06
Leakage current detection error
YesYes
E3
Code shown on the remote controller for the installation error(s): Stop valve left closed; refrigerant overcharge (Flex outdoor installation manual, test-operation table)
Not statedYes
E3-00
OU: Actuation of high pressure switch (HPS)
YesYes
E3-19
OU: Actuation of high pressure switch (HPS)
YesYes
E3-24
High pressure sensor abnormality
YesYes
E4
Code shown on the remote controller for the installation error(s): Stop valve left closed; insufficient refrigerant (Flex outdoor installation manual, test-operation table)
Not statedYes
E4-00
Abnormal suction pressure
YesYes
E4-07
Low evaporating temperature
Not statedYes
E5
Compressor motor lock
YesYes
E5-00
OU: Overheat of inverter compressor motor
NoYes
E6
Standard compressor lock or over current
YesYes
E6-00
OU: Compressor startup defect
NoYes
E7
Code shown on the remote controller for the installation error(s): Fan motor junction connectors (X1A-X4A) not reconnected after inverter service (Flex outdoor installation manual, test-operation table)
YesYes
E7-00
OU: Malfunction of outdoor unit fan motor
YesYes
E7-01
OU: Malfunction of outdoor unit fan motor
YesYes
E7-05
OU: Malfunction of outdoor unit fan motor
YesYes
E7-61
OU: Malfunction of outdoor unit fan motor
YesYes
E7-63
OU: Malfunction of outdoor unit fan motor
YesYes
E8
Input over current
YesYes
E8-00
OU: Power input overvoltage
YesYes
E9
Malfunction of moving part of electronic expansion valve (Y1E, Y3E)
Not statedYes
E9-00
Malfunction of electronic expansion valve
YesYes
E9-01
Malfunction of electronic expansion valve
YesYes
E9-02
Electronic expansion valve error due to wetness
YesYes
E9-03
Malfunction of electronic expansion valve
YesYes
EA
Heating / Cooling switching failure
Not statedYes
EA-00
OU: Cool/heat switchover problem
NoYes
EA-01
4WV switching error
YesYes
EC
Domestic hot water temperature too high
Not statedYes
EC-00
Abnormal increase tank temperature
NoYes
EC-04
Tank preheating
NoYes
EJ-01
Brine circuit pressure low
Not statedYes
F3
Code shown on the remote controller for the installation error(s): Stop valve left closed; insufficient refrigerant (Flex outdoor installation manual, test-operation table)
YesYes
F3-00
OU: Malfunction of discharge pipe temperature
NoYes
F3-01
OU: Malfunction of discharge pipe temperature
YesYes
F3-02
OU: Malfunction of discharge pipe temperature
YesYes
F3-20
OU: Malfunction of discharge pipe temperature
YesYes
F3-24
Compressor shell temperature error
YesYes
F6
Code shown on the remote controller for the installation error(s): Stop valve left closed; refrigerant overcharge (Flex outdoor installation manual, test-operation table)
Not statedYes
F6-00
OU: Abnormal high pressure in cooling
NoYes
FA-00
OU: Abnormal high pressure, actuation of HPS
NoYes
H0
Sensor abnormality
Not statedYes
H0-00
OU: Voltage/current sensor problem
YesYes
H0-02
Outdoor unit gas sensor malfunction
YesYes
H0-04
Outdoor unit gas sensor disconnection
YesYes
H1-00
External temperature sensor problem
NoYes
H3-00
OU: Malfunction of high pressure switch (HPS)
YesYes
H3-01
OU: Malfunction of high pressure switch (HPS)
YesYes
H3-08
OU: Malfunction of high pressure switch (HPS)
YesYes
H4-00
Malfunction of low pressure switch
YesYes
H5-00
Malfunction of compressor overload protection
YesYes
H6
Compressor start up failure
YesYes
H6-00
OU: Malfunction of position detection sensor
NoYes
H7-01
OU: Malfunction of outdoor unit fan motor
YesYes
H7-31
Fan motor operation hours
YesYes
H8
CT or related abnormality
YesYes
H8-00
OU: Malfunction of compressor input (CT) system
NoYes
H9
Malfunction of thermistor (R1T) for outdoor air (loose connection, disconnection, short circuit, failure)
Not statedYes
H9-00
OU: Malfunction of outdoor air thermistor
YesYes
H9-01
OU: Malfunction of outdoor air thermistor
YesYes
HC
Domestic hot water temperature thermistor abnormality
Not statedYes
HC-00
Tank temperature sensor problem
NoYes
HC-01
Second tank temperature sensor problem
NoYes
HC-02
Lower tank thermistor abnormality
NoYes
HC-09
Tank temperature sensor problem
NoYes
HJ-10
Water pressure sensor abnormality
NoYes
HJ-11
Boiler abnormality detection Check boiler Refer to boiler manual
Not statedYes
HJ-12
Bypass valve turning error
Not statedYes
J2
Current sensor malfunction
Not statedYes
J3
Malfunction of discharge pipe thermistor (R2T, R6T) (loose connection, disconnection, short circuit, failure)
Not statedYes
J3-00
OU: Malfunction of discharge pipe thermistor
YesYes
J3-01
Discharge pipe Thermistor Abnormality
YesYes
J3-10
Compressor port thermistor abnormality
YesYes
J3-47
Compressor shell thermistor abnormality
YesYes
J5
Malfunction of thermistor (R3T, R5T, R7T) for suction pipe (loose connection, disconnection, short circuit, failure)
Not statedYes
J5-00
Malfunction of suction pipe thermistor
YesYes
J5-23
Malfunction of suction pipe thermistor
YesYes
J6
Malfunction of thermistor (R6T) for heat exchanger (loose connection, disconnection, short circuit, failure)
Not statedYes
J6-00
OU: Malfunction of heat exchanger thermistor
YesYes
J6-07
OU: Malfunction of heat exchanger thermistor
YesYes
J6-31
Inlet water temperature Thermistor abnormality
YesYes
J6-32
Leaving water temperature thermistor Abnormality (outdoor unit)
NoYes
J6-33
Sensor communication error
YesYes
J6-36
OU: Malfunction of injection thermistor
YesYes
J6-42
OU: Malfunction of injection thermistor
YesYes
J7
Malfunction of thermistor (R7T) for outdoor unit liquid pipe
Not statedYes
J7-00
Malfunction of intermediate heat exchanger thermistor
YesYes
J7-12
Brine inlet thermistor abnormality
Not statedYes
J8-00
Malfunction of refrigerant liquid thermistor
YesYes
J8-07
Brine outlet thermistor abnormality
Not statedYes
J9
Malfunction of subcooling heat exchanger gas pipe thermistor (R4T)
Not statedYes
J9-23
Heat pipe thermistor abnormality
YesYes
JA
Malfunction of high pressure sensor IU/OU
Not statedYes
JA-00
OU: Malfunction of high pressure sensor
YesYes
JA-01
OU: Malfunction of high pressure sensor
YesYes
JA-17
Refrigerant pressure sensor abnormality
YesYes
JC
Malfunction of low pressure sensor IU/OU
Not statedYes
JC-00
Low pressure sensor abnormality
Not statedYes
JC-01
Evaporator pressure abnormality
YesYes
L1
Malfunction of PC board
Not statedYes
L1-00
Malfunction of INV PCB
YesYes
L1-01
Malfunction of INV PCB
YesYes
L1-02
Malfunction of INV PCB
YesYes
L1-03
Malfunction of INV PCB
YesYes
L1-04
Malfunction of INV PCB
YesYes
L1-05
Malfunction of INV PCB
YesYes
L1-06
Malfunction of INV PCB
YesYes
L1-27
Malfunction of INV PCB
YesYes
L1-31
Malfunction of INV PCB
YesYes
L1-54
Malfunction of INV PCB
NoYes
L1-55
Malfunction of INV PCB
YesYes
L3
Switch box temperature rise
Not statedYes
L3-00
OU: Electrical box temperature rise problem
YesYes
L4
Malfunction of inverter radiating fin temperature rise
YesYes
L4-00
OU: Malfunction of inverter radiating fin temperature rise
YesYes
L4-01
OU: Malfunction of inverter radiating fin temperature rise
YesYes
L4-06
OU: Malfunction of inverter radiating fin temperature rise
YesYes
L4-07
OU: Malfunction of inverter radiating fin temperature rise
YesYes
L5
Inverter compressor abnormal
YesYes
L5-00
OU: Inverter instantaneous overcurrent (DC)
YesYes
L8
Inverter current abnormal
Not statedYes
L8-00
Malfunction triggered by a thermal protection in the inverter PCB
YesYes
L8-01
Malfunction triggered by a thermal protection in the inverter PCB
YesYes
L8-02
Malfunction triggered by a thermal protection in the inverter PCB
YesYes
L8-03
Malfunction triggered by a thermal protection in the inverter PCB
YesYes
L8-04
Malfunction triggered by a thermal protection in the inverter PCB
YesYes
L8-05
Malfunction triggered by a thermal protection in the inverter PCB
YesYes
L8-14
Malfunction triggered by a thermal protection in the inverter PCB
YesYes
L9
Inverter start up error
Not statedYes
L9-00
Prevention of compressor lock
YesYes
L9-01
Malfunction in transmission system of outdoor unit
YesYes
L9-02
Malfunction in transmission system of outdoor unit
YesYes
L9-03
Malfunction in transmission system of outdoor unit
YesYes
L9-13
Malfunction in transmission system of outdoor unit
YesYes
LC
Code shown on the remote controller for the installation error(s): No power supplied to outdoor or indoor unit (including phase interruption) (Flex outdoor installation manual, test-operation table)
Not statedYes
LC-00
Malfunction in communication system of outdoor unit
YesYes
LC-01
Malfunction in communication system of outdoor unit
YesYes
LC-02
Malfunction in transmission system of outdoor unit
YesYes
LC-03
Malfunction in transmission system of outdoor unit
YesYes
LC-05
Malfunction in transmission system of outdoor unit
YesYes
LC-33
Malfunction in transmission system of outdoor unit
YesYes
LH
Converter Error
Not statedYes
LH-01
Converter error
NoYes
P1
High voltage of capacitor in main inverter circuit
Not statedYes
P1-00
Open-phase power supply imbalance
YesYes
P3-00
Abnormal direct current
YesYes
P3-01
Abnormal direct current
YesYes
P3-04
Abnormal direct current
YesYes
P4
Radiation fin thermistor or related abnormality
Not statedYes
P4-00
OU: Malfunction of radiating fin temperature sensor
YesYes
P4-01
Fin thermistor abnormality
YesYes
P4-02
Fin thermistor abnormality
YesYes
P4-03
Fin thermistor abnormality
YesYes
PJ
Faulty combination of PCB
Not statedYes
PJ-00
Capacity setting mismatch
YesYes
PJ-01
Capacity setting mismatch
YesYes
PJ-04
Inverter PCB mismatch
YesYes
PJ-09
Capacity setting mismatch
YesYes
U0
Low pressure drop due to refrigerant shortage or electronic expansion valve failure
YesYes
U0-00
OU: Shortage of refrigerant
YesYes
U0-04
OU: Shortage of refrigerant
YesYes
U0-12
Refrigerant cooling dew condensation error
YesYes
U0-13
OU: Shortage of refrigerant
YesYes
U0-14
OU: Shortage of refrigerant
YesYes
U0-23
OU: Shortage of refrigerant
YesYes
U0-36
Low refrigerant pressure
YesYes
U1
Code shown on the remote controller for the installation error(s): Phases of the outdoor power supply reversed; no power / phase interruption (Flex outdoor installation manual, test-operation table)
Not statedYes
U1-00
Malfunction by reverse phase/open-phase
YesYes
U1-01
Malfunction by reverse phase/ open-phase
YesYes
U2
Power supply insufficient or instantaneous failure
YesYes
U2-00
OU: Defect of power supply voltage
YesYes
U2-01
Supply voltage error
YesYes
U2-02
Supply voltage error
YesYes
U2-03
Supply voltage error
YesYes
U2-04
Supply voltage error
YesYes
U2-07
Supply voltage error
YesYes
U2-31
Supply voltage error
NoYes
U2-35
Supply voltage error
YesYes
U2-36
Supply voltage error
YesYes
U2-37
Supply voltage error
YesYes
U2-42
Supply voltage error
YesYes
U2-43
Supply voltage error
YesYes
U2-44
Supply voltage error
YesYes
U3
Code shown on the remote controller for the installation error(s): Test operation not performed, interrupted, or run outside -20~35 C ambient so initial refrigerant detection failed (Flex outdoor installation manual, test-operation table)
Not statedYes
U3-00
Underfloor heating screed dryout function not completed correctly
YesYes
U4
Code shown on the remote controller for the installation error(s): No power supplied to outdoor or indoor unit (including phase interruption) (Flex outdoor installation manual, test-operation table)
Not statedYes
U4-00
Indoor/outdoor unit communication problem
YesYes
U5
Malfunction of transmission between remote control and indoor unit / failure of remote control PC board or setting during control by remote control
Not statedYes
U5-00
User interface communication problem
YesYes
U6-36
Boiler standby abnormality Check boiler Refer to boiler manual
Not statedYes
U6-38
Extension/hydro communication problem
NoYes
U7
Malfunction of transmission outdoor unit
Not statedYes
U7-00
OU: Transmission malfunction between main CPU- INV CPU
YesYes
U8
Malfunction of transmission between main and sub remote controls (malfunction of sub remote control)
Not statedYes
U8-01
Connection with LAN adapter lost
YesYes
U8-02
Connection with room thermostat lost
NoYes
U8-03
No connection with room thermostat
NoYes
U8-04
Unknown USB device
NoYes
U8-05
File malfunction
NoYes
U8-06
MMI/bizone kit communication problem
YesYes
U8-07
P1P2 communication error
NoYes
U8-08
Boiler communication malfunction
Not statedYes
U8-09
MMI software version {version_MMI_software} / Indoor unit [version_IU_modelname] compatibility error
YesYes
U8-11
Connection with the Wireless gateway lost
NoYes
U8-22
Display PCB in bootloader
NoYes
U8-23
Display PCB communication issue
NoYes
U8-24
Display PCB in back port mode
NoYes
U8-25
Display PCB in self-test mode
NoYes
U8-26
Room thermostat software version compatibility error
PartlyYes
U8-27
Connection with multistep backup heater PCB lost
YesYes
U8-28
Invalid DB error Error only possible when there is a new software upload
NoYes
U8-29
EEPROM loaded with errors Error only possible when there is a new software upload
NoYes
UA
Communication error between outdoor unit and indoor unit
Not statedYes
UA-00
Indoor unit, outdoor unit matching problem
YesYes
UA-05
Indoor/outdoor combination abnormality
YesYes
UA-07
Indoor/outdoor combination abnormality
YesYes
UA-09
Indoor/outdoor combination abnormality
YesYes
UA-16
Extension/hydro communication problem
NoYes
UA-17
Tank type problem
YesYes
UA-21
Extension/hydro mismatch problem
YesYes
UA-22
Communication problem between control box and option box
YesYes
UA-48
Outdoor unit standby power connector connection error
NoYes
UA-52
Boiler, indoor unit matching problem
Not statedYes
UA-59
HPSU/hydro combination abnormality
YesYes
UA-60
PCB combination malfunction
YesYes
UF
Code shown on the remote controller for the installation error(s): Stop valve left closed; incorrect interconnections between units (piping and wiring inconsistent); refrigerant overcharge (Flex outdoor installation manual, test-operation table)
Not statedYes
UF-00
Reversed piping or bad communication wiring detection
YesYes
UF-01
Indoor/outdoor miswiring detection
YesYes
UF-02
Reversed piping or bad communication wiring detection
YesYes
UH
Malfunction of system, refrigerant system address undefined
Not statedYes
UH-17
Indoor unit locked (R290)
Not statedYes
UH-18
Outdoor unit locked (R290)
YesYes
UH-19
Too many attempts to unlock the unit
NoYes
UJ-14
AF communication error
NoYes
UJ-20
AF warning
NoYes
UJ-26
AF caution
NoYes