HJ-10Daikin · Altherma

HJ-10 on a Daikin Altherma: Water pressure sensor abnormality

Short answer

On a Daikin heat pump, HJ-10 means: Water pressure sensor abnormality. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Water pressure sensor abnormality.

Part involved: water pressure sensor.

When it shows: Water pressure input is out of range.

Likely causes:

  • Main water supply or pressure outside expected range.; Leak in the water circuit.; Faulty water pressure sensor.; Faulty hydro PCB.

Is it safe?

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: yes.

Manual reset: Automatic reset when water pressure is within range.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).
  • Daikin documents this code as resetting automatically once the condition clears; if it keeps coming back, contact your installer.
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

  • | Troubleshooting ; Check the main water supply and pressure of the installation. . ; Check for leaks in the water circuit. . ; Perform a check of the water pressure sensor. . ; Perform a check of the hydro PCB. .

Who to ask for: Heat pump installer / heating engineer.

Certification: None specific for water-side checks; MCS-certified installer recommended.

What you might notice

What owners and engineers report

14 owner and engineer reports mention this.

  • No heating on the Altherma: 7 reports
  • Pressure keeps dropping on the Altherma: 3 reports
  • Keeps stopping / cutting out on the Altherma: 2 reports
  • No hot water on the Altherma: 2 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026