HJ-10 on a Daikin Altherma: Water pressure sensor abnormality
Short answer
On a Daikin heat pump, HJ-10 means: Water pressure sensor abnormality. The heat pump keeps running. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Water pressure sensor abnormality.
Part involved: water pressure sensor.
When it shows: Water pressure input is out of range.
Likely causes:
- Main water supply or pressure outside expected range.; Leak in the water circuit.; Faulty water pressure sensor.; Faulty hydro PCB.
Is it safe?
| Does the heat pump stop? | No |
|---|---|
| Severity | Warning |
| Engineer needed? | Yes |
The heat pump keeps running.
Resetting itself: yes.
Manual reset: Automatic reset when water pressure is within range.
What you can check
- Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
- Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).
- Daikin documents this code as resetting automatically once the condition clears; if it keeps coming back, contact your installer.
- Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
- If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.
What the engineer will check
- | Troubleshooting ; Check the main water supply and pressure of the installation. . ; Check for leaks in the water circuit. . ; Perform a check of the water pressure sensor. . ; Perform a check of the hydro PCB. .
Who to ask for: Heat pump installer / heating engineer.
Certification: None specific for water-side checks; MCS-certified installer recommended.
What you might notice
What owners and engineers report
14 owner and engineer reports mention this.
- No heating on the Altherma: 7 reports
- Pressure keeps dropping on the Altherma: 3 reports
- Keeps stopping / cutting out on the Altherma: 2 reports
- No hot water on the Altherma: 2 reports
Sources
- Service manual Daikin Altherma 3 M EBLA/EDLA04~08E (ESIE22-09) ↗ · ESIE22-09 · page 58 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026