8F-00 on a Daikin Altherma: Abnormal increase outlet water temperature (DHW)

Short answer

On a Daikin heat pump, 8F-00 means: Abnormal increase outlet water temperature (DHW). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Abnormal increase outlet water temperature (DHW).

Part involved: DHW tank temperature.

When it shows: Outlet water after backup heater thermistor detects a too high temperature during domestic hot water without electrical heater.

Likely causes:

  • Water flow is too low.; Faulty outlet water after backup heater thermistor.; Clogged water circuit.; Faulty water pump.; Faulty backup heater contactor(s).

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Manual reset via user interface.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check the domestic hot water / programme schedule and settings on the user interface (Daikin notes AH-00 can be caused by large hot-water draws or stopping the tank during disinfection).
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.

What the engineer will check

  • Check the water flow. . ; Perform a check of the outlet water after backup heater thermistor. . ; | Troubleshooting ; Check if the water circuit is clogged. . ; Perform a check of the water pump. . ; Perform a check of the backup heater contactor(s). .

Who to ask for: Heat pump installer / heating engineer.

Certification: G3 unvented hot water competence for cylinder safety components.

What you might notice

What owners and engineers report

5 owner and engineer reports mention this.

  • Hot water not hot enough on the Altherma: 5 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026