SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Daikin
7H-05Daikin · Altherma

7H-05 on a Daikin Altherma: Water flow problem during heating/sampling

Short answer

On a Daikin heat pump, 7H-05 means: Water flow problem during heating/sampling. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Water flow problem during heating/sampling.

Part involved: water flow / circulation pump / flow sensor.

When it shows: Water flow abnormality determined mainly during space heating.

Likely causes:

  • Closed stop valve in the water circuit.; Air in the water circuit.; Water flow is too low.; Water pressure is too low.; No by‑pass installed in the water circuit.; Faulty water flow sensor.; Faulty 3‑way valve.; Faulty water pump.; Faulty hydro PCB.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Manual reset via user interface.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

  • Check that all stop valves of the water circuit are open. . ; Purge the water circuit. . ; Check the water flow. . ; Check the water pressure. . ; Check if a by‑pass is installed in the water circuit. . ; Perform an electrical check of the water flow sensor. . ; Perform a check of the 3-way valve. . ; Perform a check of the water pump. . ; Perform a check of the hydro PCB. . ; | Troubleshooting.

Who to ask for: Heat pump installer / heating engineer.

Certification: None specific for water-side checks; MCS-certified installer recommended.

What you might notice

What owners and engineers report

13 owner and engineer reports mention this.

  • No heating on the Altherma: 7 reports
  • Keeps stopping / cutting out on the Altherma: 2 reports
  • No hot water on the Altherma: 2 reports
  • Radiators cold on the Altherma: 2 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026