8H-00 on a Daikin heat pump: Abnormal increase outlet water temperature

Short answer

On a Daikin heat pump, 8H-00 means: Abnormal increase outlet water temperature. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma

The manual says: Abnormal increase outlet water temperature.

Part involved: water circuit temperature protection.

When it shows: Outlet water after backup heater thermistor detects a too high temperature during space heating without electrical heater.

Likely causes:

  • Water flow is too low.; Faulty outlet water after backup heater thermistor.; Clogged water circuit.; Faulty water pump.; Faulty backup heater contactor(s).

On the Altherma 4 H (R-290)

The manual says: Overheating of the space heating water circuit.

Part involved: water circuit temperature protection.

When it shows: The maximum water temperature in the space heating water circuit is above the overheating temperature.

Is it safe?

On the Altherma

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Manual reset via user interface.

On the Altherma 4 H (R-290)

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Automatic.

What you can check

On the Altherma

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

On the Altherma 4 H (R-290)

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).
  • Daikin documents this code as resetting automatically once the condition clears; if it keeps coming back, contact your installer.
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

On the Altherma

  • Check the water flow. . ; Perform a check of the outlet water after backup heater thermistor. . ; Check if the water circuit is clogged. . ; Perform a check of the water pump. . ; Perform a check of the backup heater contactor(s). . ; | Troubleshooting.

Who to ask for: Heat pump installer / heating engineer.

Certification: None specific for water-side checks; MCS-certified installer recommended.

On the Altherma 4 H (R-290)

  • See Daikin service manual for this generation (not public).

Who to ask for: Heat pump installer / heating engineer.

Certification: None specific for water-side checks; MCS-certified installer recommended.

What you might notice

What owners and engineers report

11 owner and engineer reports mention this.

  • No heating on the Altherma: 7 reports
  • Keeps stopping / cutting out on the Altherma: 2 reports
  • No hot water on the Altherma: 2 reports

Sources

A code explains what the controller detected, not a confirmed root cause.