AA-00 on a Daikin Altherma LT monobloc: Back up heater safety error

Short answer

On a Daikin heat pump, AA-00 means: Back up heater safety error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Back up heater safety error.

Part involved: backup heater / thermal protector.

When it shows: Thermal protector Q1L is activated (open circuit). Water temp > 90°C.

Likely causes:

  • Air in water circuit / backup heater.; Faulty thermal protector Q1L.; Faulty outlet backup heater thermistor.; Faulty outlet water heat exchanger thermistor.; Faulty backup heater assy.; Faulty wiring between outdoor unit Control box DHW tank.; Faulty backup heater.; Water pressure is too low.; Water flow is too low.; Faulty extension PCB A4P.

Is it safe?

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Power reset + reset via user interface + pressing the button on the Q1L (if activated).

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).

What the engineer will check

Who to ask for: Heat pump installer with electrical competence.

Certification: Electrical competence to BS 7671 for heater/thermal cut-out work.

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • No heating on the Altherma LT monobloc: 1 report
  • No hot water on the Altherma LT monobloc: 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026