L9Daikin · Altherma HT (high temperature split)

L9 on a Daikin Altherma HT: Inverter start up error

Short answer

On a Daikin heat pump, L9 means: Inverter start up error. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Inverter start up error.

Part involved: compressor / inverter drive.

When it shows: When overload in the compressor is detected during startup.

Likely causes:

  • Defect of compressor; Pressure differential start; Defect of outdoor unit PC board (A2P); Defect of outdoor unit PC board [A4P (1 ø) or A5P (3ø)].

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.

What the engineer will check

  • Follow the service-manual troubleshooting flow chart for this code: check defect of compressor; check pressure differential start; check defect of outdoor unit PC board (A2P); check defect of outdoor unit PC board [A4P (1 ø) or A5P (3ø)].

Who to ask for: F-gas certified heat pump engineer with electrical competence.

Certification: UK F-gas certification if the refrigerant circuit is opened; electrical competence (BS 7671) for inverter/PCB work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.