L1-00 on a Daikin Altherma: Malfunction of INV PCB
Short answer
On a Daikin heat pump, L1-00 means: Malfunction of INV PCB. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Malfunction of INV PCB.
Part involved: PCB / capacity setting.
When it shows: Outdoor unit main PCB detects current/voltage errors.
Likely causes:
- ▪ Faulty or disturbance of the power supply (power supply MUST be within range of nominal operating voltage ±4%), ▪ Power drop, ▪ Short circuit.; Faulty main PCB.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: no.
Manual reset: Manual reset via user interface. Power reset.
What you can check
- Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
- Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.
- Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
- If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.
What the engineer will check
- | Troubleshooting ; Check if the power supply is compliant with the regulations. . ; Perform a check of the main PCB. .
Who to ask for: Heat pump engineer (Daikin-trained).
Certification: Electrical competence to BS 7671 for PCB replacement.
What you might notice
What owners and engineers report
12 owner and engineer reports mention this.
- No heating on the Altherma: 7 reports
- Heat pump will not start on the Altherma: 5 reports
Sources
- Service manual Daikin Altherma 3 M EBLA/EDLA04~08E (ESIE22-09) ↗ · ESIE22-09 · page 61 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026