SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Daikin
UJ-26Daikin · Altherma

UJ-26 on a Daikin Altherma: AF caution

Short answer

On a Daikin heat pump, UJ-26 means: AF caution. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: AF caution.

Part involved: inter-unit communication / PCB combination.

When it shows: Active filter operation caution. NOTICE the water volume and flow rate" NOTICE NOTICE INFORMATION ▪ stuck BSH relay. ▪ displayed. ▪ During because the disinfection. INFORMATION consumption control. INFORMATION certified technician. NOTICE INFORMATION ▪ "2 ▪ "3.1 15.1.1 Use the service ports (a)(b) to recover refrigerant.

Is it safe?

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: yes.

Manual reset: Automatic To check If error EC-00 is displayed, indicating overheating of the tank, it could be due to a (weekly), the error code AH-00 is displayed requested temperature required for tank MUST be treated at a specialised treatment facility for reuse, recycling and recovery. [4 22] To recover refrigerant............................................................................................................................................................224 To manually open the electronic expansion valves..............................................................................................227.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Daikin documents this code as resetting automatically once the condition clears; if it keeps coming back, contact your installer.
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

  • See Daikin service manual for this generation (not public).

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

What you might notice

What owners and engineers report

13 owner and engineer reports mention this.

  • No heating on the Altherma: 7 reports
  • Controller / thermostat problem on the Altherma: 6 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026