F3-24 on a Daikin heat pump: Compressor shell temperature error

Short answer

On a Daikin heat pump, F3-24 means: Compressor shell temperature error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma 3 H HT (R-32 high temperature split)

The manual says: Compressor shell temperature error.

Part involved: refrigerant circuit / pressure protection.

When it shows: Compressor shell thermistor temperature <Tc (saturated condensation temperature) – 1 K for 30 minutes after compressor start‑up. EPRA14~18D + ETSH/X(B)16P30+50E Daikin Altherma 3 H HT ECH₂O 3 | Troubleshooting.

Likely causes:

  • Faulty compressor shell thermistor or connector fault.

On the Altherma 4 H (R-290)

The manual says: OU: Malfunction of discharge pipe temperature.

Part involved: refrigerant circuit / pressure protection.

When it shows: Loosehanging compressor shell thermistor.

Is it safe?

On the Altherma 3 H HT (R-32 high temperature split)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Manual reset via user interface.

On the Altherma 4 H (R-290)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Manual.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

On the Altherma 3 H HT (R-32 high temperature split)

  • Perform a check of the compressor shell thermistor.

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

On the Altherma 4 H (R-290)

  • See Daikin service manual for this generation (not public).

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • No heating on the Altherma 3 H HT (R-32 high temperature split): 1 report
  • No hot water on the Altherma 3 H HT (R-32 high temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026