UA-59 on a Daikin Altherma 3 H HT: HPSU/hydro combination abnormality

Short answer

On a Daikin heat pump, UA-59 means: HPSU/hydro combination abnormality. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: HPSU/hydro combination abnormality.

Part involved: inter-unit communication / PCB combination.

When it shows: Hydro extension PCB has detected mismatch in communication with hydro PCB.

Likely causes:

  • Mismatch between the hydro software version and the hydro extension PCB. Hydro PCB needs to be loaded with "HPSU version" software.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Power reset.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

  • Check the software and EEPROM version on the user interface and PCB.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma 3 H HT (R-32 high temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026