Heat pumps · Error codes · Daikin
A5-00Daikin · Altherma

A5-00 on a Daikin Altherma: OU: High pressure peak cut / freeze protection problem

Short answer

On a Daikin heat pump, A5-00 means: OU: High pressure peak cut / freeze protection problem. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: OU: High pressure peak cut / freeze protection problem.

Part involved: plate heat exchanger freeze protection.

When it shows: Pressure is too high in heating / domestic hot water, too low in cooling.

Likely causes:

  • Water pressure is too low.; Water flow is too low.; Closed stop valve in the water circuit.; Air in the water circuit.; Faulty ambient air thermistor.; Faulty expansion valve.; Closed stop valve in the refrigerant circuit.; Clogged refrigerant circuit.; Refrigerant overcharge or shortage.; Non‑condensables and/or humidity in the refrigerant circuit.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Manual reset via user interface.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

  • Check the water pressure. . ; Check the water flow. . ; Check that all stop valves of the water circuit are open. . ; Purge the water circuit. . ; Perform a check of the outdoor air thermistor. . ; Perform a check of the expansion valve. . ; Check that all stop valves of the refrigerant circuit are open. . ; Check if the refrigerant circuit is clogged. . ; Check if the refrigerant circuit is correctly charged. . ; Check for the presence of non‑condensables and/or humidity in the refrigerant circuit. . ; | Troubleshooting.

Who to ask for: Heat pump installer / heating engineer.

Certification: None specific for water-side checks; MCS-certified installer recommended.

What you might notice

What owners and engineers report

17 owner and engineer reports mention this.

  • No heating on the Altherma: 7 reports
  • Pressure keeps dropping on the Altherma: 3 reports
  • Keeps stopping / cutting out on the Altherma: 2 reports
  • No hot water on the Altherma: 2 reports
  • Stops working in very cold weather on the Altherma: 2 reports
  • Frequent defrosting on the Altherma: 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026