SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Daikin
CJ-02Daikin · Altherma

CJ-02 on a Daikin Altherma: Room temperature sensor problem

Short answer

On a Daikin heat pump, CJ-02 means: Room temperature sensor problem. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Room temperature sensor problem.

Part involved: user interface / room thermostat.

When it shows: User interface room thermistor input is out of range.

Likely causes:

  • Faulty room thermistor.; Faulty wiring between the remote controller and the unit.; Faulty hydro PCB.

Is it safe?

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: yes.

Manual reset: Automatic reset.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check any room thermostat/controller display is lit and its batteries (if battery-powered) are not flat; check thermostat and schedule settings.
  • Daikin documents this code as resetting automatically once the condition clears; if it keeps coming back, contact your installer.
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

  • Perform a check of the room thermistor: ▪ Measure the room temperature and compare to the room temperature shown on the user interface (remote controller). ▪ If temperature shown on the user interface differs from the measured temperature, replace the user interface (remote controller). See documentation of the user interface (remote controller) for more information. ; Check the communication wiring between the remote controller and the unit. . ; Perform a check of the hydro PCB. .

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

What you might notice

What owners and engineers report

13 owner and engineer reports mention this.

  • No heating on the Altherma: 7 reports
  • Controller / thermostat problem on the Altherma: 6 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026