E3Daikin

E3 on a Daikin heat pump: Code shown on the remote controller for the installation error(s): Stop valve left closed; refrigerant overcharge (Flex outdoor installation manual, test-operation table)

Short answer

On a Daikin heat pump, E3 means: Code shown on the remote controller for the installation error(s): Stop valve left closed; refrigerant overcharge (Flex outdoor installation manual, test-operation table). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma Flex Type

The manual says: Code shown on the remote controller for the installation error(s): Stop valve left closed; refrigerant overcharge (Flex outdoor installation manual, test-operation table).

Part involved: refrigerant circuit / pressure protection.

When it shows: Detected during test operation / normal operation after installation errors listed.

Likely causes:

  • Stop valve left closed; refrigerant overcharge.

On the Altherma HT (high temperature split)

The manual says: Actuation of high pressure switch.

Part involved: refrigerant circuit / pressure protection.

When it shows: Error is generated when the HPS activation count reaches the number specific to the operation mode. (Reference) Operating pressure of high pressure switch Operating pressure: 4.0MPa Reset pressure: 3.0MPa | Error is generated when the HPS activation count reaches the number specific to the operation mode. (Reference) Operating pressure of high pressure switch Operating pressure: 3.8MPa Reset pressure: 2.7MPa.

Likely causes:

  • Actuation of outdoor unit high pressure switch; Defect of High pressure switch; Defect of outdoor unit PC board (A1P); Instantaneous power failure; Faulty high pressure sensor; Actuation of indoor unit high pressure switch; Defect of Indoor unit PC board (A4P); Refrigerant blockage; Water blockage; Thermal cut out error (Q2L) Warning: CAPACITOR SHOCK HAZARD. The capac itors (top surfaces) can hold up to 220V. Use correct precautions when servicing.

Is it safe?

On the Altherma Flex Type

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: After correcting the abnormality press BS3 RETURN on the outdoor PCB to reset and repeat the test operation (installer only).

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).

What the engineer will check

On the Altherma Flex Type

  • Installer remedial action per manual: open stop valves; correct phase sequence; check power wiring; check piping/wiring consistency; correct refrigerant charge by recalculation; repeat test operation within -20~35 C.

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

On the Altherma HT (high temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check actuation of outdoor unit high pressure switch; check defect of High pressure switch; check defect of outdoor unit PC board (A1P); check instantaneous power failure; check faulty high pressure sensor; check actuation of indoor unit high pressure switch.

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026