E7 on a Daikin heat pump: Code shown on the remote controller for the installation error(s): Fan motor junction connectors (X1A-X4A) not reconnected after inverter service (Flex outdoor installation manual, test-operation table)

Short answer

On a Daikin heat pump, E7 means: Code shown on the remote controller for the installation error(s): Fan motor junction connectors (X1A-X4A) not reconnected after inverter service (Flex outdoor installation manual, test-operation table). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Altherma Flex Type

The manual says: Code shown on the remote controller for the installation error(s): Fan motor junction connectors (X1A-X4A) not reconnected after inverter service (Flex outdoor installation manual, test-operation table).

Part involved: outdoor fan motor.

When it shows: Detected during test operation / normal operation after installation errors listed.

Likely causes:

  • Fan motor junction connectors (X1A-X4A) not reconnected after inverter service.

On the Altherma HT (high temperature split)

The manual says: Malfunction of outdoor unit fan motor.

Part involved: outdoor fan motor.

When it shows:  When the fan runs with speed less than a spec ified one for 6 seconds or more when the fan motor running conditions are met  When malfunction is generated 4 ti mes, the system shuts down.

Likely causes:

  • Malfunction of fan motor; The harness connector between fan motor and PC board is left in disconnected, or faulty connector; Fan does not run due to foreign matters tangled; Clearing condition: Operate for 5 minutes (normal); Open phase L1 or open phase N. ESIE09-08C.

On the Altherma LT (low temperature split)

The manual says: DC fan lock.

Part involved: outdoor fan motor.

When it shows: ■ The fan does not start in 30 seconds even when the fan motor is running. ■ The system will be shut down if the error occurs 16 times. ■ Clearing condition: Continuous run for about 5 minutes (normal) | The fan does not start in 30 seconds even when the fan motor is running. The system will be shut down if the error occurs 16 times. Clearing condition: Continuous run for about 5 minutes (normal).

Likely causes:

  • Fan motor breakdown; Harness or connector disconnected between fan motor and PCB or in poor contact; Foreign matters stuck in the fan.

Is it safe?

On the Altherma Flex Type

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: After correcting the abnormality press BS3 RETURN on the outdoor PCB to reset and repeat the test operation (installer only).

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Altherma LT (low temperature split)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).

What the engineer will check

On the Altherma Flex Type

  • Installer remedial action per manual: open stop valves; correct phase sequence; check power wiring; check piping/wiring consistency; correct refrigerant charge by recalculation; repeat test operation within -20~35 C.

Who to ask for: Heat pump engineer (Daikin-trained).

Certification: Electrical competence to BS 7671; F-gas if refrigerant circuit affected.

On the Altherma HT (high temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check malfunction of fan motor; check the harness connector between fan motor and PC board is left in disconnected, or faulty connector; check fan does not run due to foreign matters tangled; check clearing condition: Operate for 5 minutes (normal); check open phase L1 or open phase N. ESIE09-08C.

Who to ask for: Heat pump engineer (Daikin-trained).

Certification: Electrical competence to BS 7671; F-gas if refrigerant circuit affected.

On the Altherma LT (low temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check fan motor breakdown; check harness or connector disconnected between fan motor and PCB or in poor contact; check foreign matters stuck in the fan.

Who to ask for: Heat pump engineer (Daikin-trained).

Certification: Electrical competence to BS 7671; F-gas if refrigerant circuit affected.

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • No heating on the Altherma LT (low temperature split): 1 report
  • Outdoor fan not spinning on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026