F6Daikin

F6 on a Daikin heat pump: Code shown on the remote controller for the installation error(s): Stop valve left closed; refrigerant overcharge (Flex outdoor installation manual, test-operation table)

Short answer

On a Daikin heat pump, F6 means: Code shown on the remote controller for the installation error(s): Stop valve left closed; refrigerant overcharge (Flex outdoor installation manual, test-operation table). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma Flex Type

The manual says: Code shown on the remote controller for the installation error(s): Stop valve left closed; refrigerant overcharge (Flex outdoor installation manual, test-operation table).

Part involved: refrigerant circuit / pressure protection.

When it shows: Detected during test operation / normal operation after installation errors listed.

Likely causes:

  • Stop valve left closed; refrigerant overcharge.

On the Altherma LT (low temperature split)

The manual says: Too high condensing pressure.

Part involved: refrigerant circuit / pressure protection.

When it shows: Activated when the temperature being sensed by the heat exchanger thermistor rises above 60°C. (Deactivated when the said temperature drops below 50°C) | Activated when the temperature being sensed by the heat exchanger thermistor rises above 60°C. (Deactivated when the said temperature drops below 50°C) 3 3.

Likely causes:

  • The installation space is not large enough; Faulty outdoor unit fan; Faulty electronic expansion valve; Faulty defrost thermistor; Faulty outdoor unit PCB; Faulty stop valve; Dirty heat exchanger.

Is it safe?

On the Altherma Flex Type

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: After correcting the abnormality press BS3 RETURN on the outdoor PCB to reset and repeat the test operation (installer only).

On the Altherma LT (low temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).

What the engineer will check

On the Altherma Flex Type

  • Installer remedial action per manual: open stop valves; correct phase sequence; check power wiring; check piping/wiring consistency; correct refrigerant charge by recalculation; repeat test operation within -20~35 C.

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

On the Altherma LT (low temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check the installation space is not large enough; check faulty outdoor unit fan; check faulty electronic expansion valve; check faulty defrost thermistor; check faulty outdoor unit PCB; check faulty stop valve.

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026