LC on a Daikin heat pump: Code shown on the remote controller for the installation error(s): No power supplied to outdoor or indoor unit (including phase interruption) (Flex outdoor installation manual, test-operation table)

Short answer

On a Daikin heat pump, LC means: Code shown on the remote controller for the installation error(s): No power supplied to outdoor or indoor unit (including phase interruption) (Flex outdoor installation manual, test-operation table). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma Flex Type

The manual says: Code shown on the remote controller for the installation error(s): No power supplied to outdoor or indoor unit (including phase interruption) (Flex outdoor installation manual, test-operation table).

Part involved: inter-unit communication / PCB combination.

When it shows: Detected during test operation / normal operation after installation errors listed.

Likely causes:

  • No power supplied to outdoor or indoor unit (including phase interruption).

On the Altherma HT (high temperature split)

The manual says: Malfunction of transmission between inverter and control PC board.

Part involved: inter-unit communication / PCB combination.

When it shows: When the correct communication is not conducted in certain period.

Likely causes:

  • Malfunction of connection between the inve rter microcomputer and outdoor control microcomputer; Defect of outdoor unit PC board (A1P) or inverter PC board (A2P); External factor (Noise etc.); Malfunction of connection between the inve rter microcomputer and indoor control microcomputer; Defect of indoor unit PC board [A4P (1 ø) or A5P (3ø)].

Is it safe?

On the Altherma Flex Type

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: After correcting the abnormality press BS3 RETURN on the outdoor PCB to reset and repeat the test operation (installer only).

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.

What the engineer will check

On the Altherma Flex Type

  • Installer remedial action per manual: open stop valves; correct phase sequence; check power wiring; check piping/wiring consistency; correct refrigerant charge by recalculation; repeat test operation within -20~35 C.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

On the Altherma HT (high temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check malfunction of connection between the inve rter microcomputer and outdoor control microcomputer; check defect of outdoor unit PC board (A1P) or inverter PC board (A2P); check external factor (Noise etc.); check malfunction of connection between the inve rter microcomputer and indoor control microcomputer; check defect of indoor unit PC board [A4P (1 ø) or A5P (3ø)].

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.