Heat pumps
Heat pumps · Error codes · Daikin
F3Daikin

F3 on a Daikin heat pump: Code shown on the remote controller for the installation error(s): Stop valve left closed; insufficient refrigerant (Flex outdoor installation manual, test-operation table)

Short answer

On a Daikin heat pump, F3 means: Code shown on the remote controller for the installation error(s): Stop valve left closed; insufficient refrigerant (Flex outdoor installation manual, test-operation table). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Altherma Flex Type

The manual says: Code shown on the remote controller for the installation error(s): Stop valve left closed; insufficient refrigerant (Flex outdoor installation manual, test-operation table).

Part involved: refrigerant circuit / pressure protection.

When it shows: Detected during test operation / normal operation after installation errors listed.

Likely causes:

  • Stop valve left closed; insufficient refrigerant.

On the Altherma HT (high temperature split)

The manual says: Abnormal discharge pipe temperature.

Part involved: refrigerant circuit / pressure protection.

When it shows: When the discharge pipe temperature rises to an abnormally high level When the discharge pipe temperature rises suddenly.

Likely causes:

  • Faulty discharge pipe temperature sensor; Faulty connection of dischar ge pipe temperature sensor; Faulty outdoor unit PC board; Faulty discharge pipe temperature sensor (R6T); Faulty indoor unit PC board.

On the Altherma LT (low temperature split)

The manual says: Discharge pipe temperature control.

Part involved: refrigerant circuit / pressure protection.

When it shows: ■ If a stop takes place 6 times successively due to abnormal discharge pipe temperature, the system will be shut down. ■ If the temperature being detected by the discharge pipe thermistor rises above °C, the compressor will stop. (The error is cleared when the temperature has dropped below °C. ■ The error counter will reset itself if this or any other error does not occur during the following 60-minute compressor running time (total time) | If a stop takes place 6 times successively due to abnormal discharge pipe temperature, the system will be shut down. If the temperature being detected by the discharge pipe thermistor rises above °C, the 3 3 compressor will stop. (The error is cleared when the temperature has dropped below °C. 71 class 120 107 The error counter will reset itself if this or any other error does not occur during the following 60-minute compressor running time (total time).

Likely causes:

  • Refrigerant shortage; Four way valve malfunctioning; Discharge pipe thermistor defective (heat exchanger or outdoor temperature thermistor defective); Outdoor unit PCB defective; Water mixed in the local piping; Electronic expansion valve defective; Stop valve defective 006~008 class 120 107; Discharge pipe thermistor defective; (heat exchanger or outdoor temperature thermistor defective); Stop valve defective.

Is it safe?

On the Altherma Flex Type

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: After correcting the abnormality press BS3 RETURN on the outdoor PCB to reset and repeat the test operation (installer only).

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Altherma LT (low temperature split)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).

What the engineer will check

On the Altherma Flex Type

  • Installer remedial action per manual: open stop valves; correct phase sequence; check power wiring; check piping/wiring consistency; correct refrigerant charge by recalculation; repeat test operation within -20~35 C.

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

On the Altherma HT (high temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check faulty discharge pipe temperature sensor; check faulty connection of dischar ge pipe temperature sensor; check faulty outdoor unit PC board; check faulty discharge pipe temperature sensor (R6T); check faulty indoor unit PC board.

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

On the Altherma LT (low temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check refrigerant shortage; check four way valve malfunctioning; check discharge pipe thermistor defective (heat exchanger or outdoor temperature thermistor defective); check outdoor unit PCB defective; check water mixed in the local piping; check electronic expansion valve defective.

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026