Heat pumps · Error codes · Daikin
U3Daikin · Altherma Flex Type

U3 on a Daikin Altherma Flex Type: Code shown on the remote controller for the installation error(s): Test operation not performed, interrupted, or run outside -20~35 C ambient so initial refrigerant detection failed (Flex outdoor installation manual, test-operation table)

Short answer

On a Daikin heat pump, U3 means: Code shown on the remote controller for the installation error(s): Test operation not performed, interrupted, or run outside -20~35 C ambient so initial refrigerant detection failed (Flex outdoor installation manual, test-operation table). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Code shown on the remote controller for the installation error(s): Test operation not performed, interrupted, or run outside -20~35 C ambient so initial refrigerant detection failed (Flex outdoor installation manual, test-operation table).

Part involved: underfloor screed dry-out function.

When it shows: Detected during test operation / normal operation after installation errors listed.

Likely causes:

  • Test operation not performed, interrupted, or run outside -20~35 C ambient so initial refrigerant detection failed.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: After correcting the abnormality press BS3 RETURN on the outdoor PCB to reset and repeat the test operation (installer only).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the domestic hot water / programme schedule and settings on the user interface (Daikin notes AH-00 can be caused by large hot-water draws or stopping the tank during disinfection).

What the engineer will check

  • Installer remedial action per manual: open stop valves; correct phase sequence; check power wiring; check piping/wiring consistency; correct refrigerant charge by recalculation; repeat test operation within -20~35 C.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026