Heat pumps · Error codes · Daikin
U4Daikin

U4 on a Daikin heat pump: Code shown on the remote controller for the installation error(s): No power supplied to outdoor or indoor unit (including phase interruption) (Flex outdoor installation manual, test-operation table)

Short answer

On a Daikin heat pump, U4 means: Code shown on the remote controller for the installation error(s): No power supplied to outdoor or indoor unit (including phase interruption) (Flex outdoor installation manual, test-operation table). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Altherma Flex Type

The manual says: Code shown on the remote controller for the installation error(s): No power supplied to outdoor or indoor unit (including phase interruption) (Flex outdoor installation manual, test-operation table).

Part involved: inter-unit communication / PCB combination.

When it shows: Detected during test operation / normal operation after installation errors listed.

Likely causes:

  • No power supplied to outdoor or indoor unit (including phase interruption).

On the Altherma HT (high temperature split)

The manual says: Malfunction of transmission between indoor and outdoor unit.

Part involved: inter-unit communication / PCB combination.

When it shows: When transmission is not carried out no rmally for a certain amount of time.

Likely causes:

  • Indoor to outdoor transmission wiring F1, F2 disconnection, short circuit or wrong wiring; Outdoor unit power supply is OFF; Defect of outdoor unit PC board; Defect of indoor unit PC board (A1P) ESIE09-08C; Wrong wiring between indoor unit PC boards. [A4P (1 ø) or A5P (3ø)] and A1P.

On the Altherma LT (low temperature split)

The manual says: Signal transmission error (indoor outdoor unit).

Part involved: inter-unit communication / PCB combination.

When it shows: When the data sent from the outdoor unit cannot be received normally, or when the content of the data is abnormal | When the data sent from the outdoor unit cannot be received normally, or when the content of the data is abnormal. 3 3.

Likely causes:

  • Faulty outdoor unit PCB; Faulty hydro-box PCB; Hydro-box-outdoor unit signal transmission error due to wiring error; Hydro-box-outdoor unit signal transmission error due to disturbed power supply waveform; Hydro-box-outdoor unit signal transmission error due to breaking of wire in the connection wires between the Hydro-box and outdoor units; Hydro-box -outdoor unit signal transmission error due to breaking of wire in the connection; wires between the Hydro-box and outdoor units.

Is it safe?

On the Altherma Flex Type

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: After correcting the abnormality press BS3 RETURN on the outdoor PCB to reset and repeat the test operation (installer only).

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Altherma LT (low temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.

What the engineer will check

On the Altherma Flex Type

  • Installer remedial action per manual: open stop valves; correct phase sequence; check power wiring; check piping/wiring consistency; correct refrigerant charge by recalculation; repeat test operation within -20~35 C.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

On the Altherma HT (high temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check indoor to outdoor transmission wiring F1, F2 disconnection, short circuit or wrong wiring; check outdoor unit power supply is OFF; check defect of outdoor unit PC board; check defect of indoor unit PC board (A1P) ESIE09-08C; check wrong wiring between indoor unit PC boards. [A4P (1 ø) or A5P (3ø)] and A1P.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

On the Altherma LT (low temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check faulty outdoor unit PCB; check faulty hydro-box PCB; check hydro-box-outdoor unit signal transmission error due to wiring error; check hydro-box-outdoor unit signal transmission error due to disturbed power supply waveform; check hydro-box-outdoor unit signal transmission error due to breaking of wire in the connection wires between the Hydro-box and outdoor units; check hydro-box -outdoor unit signal transmission error due to breaking of wire in the connection.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026