E7-00 on a Daikin Altherma: OU: Malfunction of outdoor unit fan motor
Short answer
On a Daikin heat pump, E7-00 means: OU: Malfunction of outdoor unit fan motor. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: OU: Malfunction of outdoor unit fan motor.
Part involved: outdoor fan motor.
When it shows: Fan does NOT start 15~30 seconds after ON signal. It can occur that the error code is triggered when the fan motor is running caused by a faulty rotating sensor signal.
Likely causes:
- Faulty outdoor unit fan motor.; Faulty main PCB.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: no.
Manual reset: Manual reset via user interface.
What you can check
- Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
- Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.
- Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).
- Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
- If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.
What the engineer will check
- Perform a check of the outdoor unit fan motor. . ; Perform a check of the main PCB. .
Who to ask for: Heat pump engineer (Daikin-trained).
Certification: Electrical competence to BS 7671; F-gas if refrigerant circuit affected.
What you might notice
What owners and engineers report
9 owner and engineer reports mention this.
- No heating on the Altherma: 7 reports
- Keeps stopping / cutting out on the Altherma: 2 reports
Sources
- Service manual Daikin Altherma 3 M EBLA/EDLA04~08E (ESIE22-09) ↗ · ESIE22-09 · page 47 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026