UA-16 on a Daikin Altherma: Extension/hydro communication problem

Short answer

On a Daikin heat pump, UA-16 means: Extension/hydro communication problem. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Extension/hydro communication problem.

Part involved: inter-unit communication / PCB combination.

When it shows: Communication abnormality between hydro PCB and hydro extension PCB.

Likely causes:

  • Faulty wiring between the hydro PCB and hydro extension PCB.; ▪ Faulty or disturbance of the power supply (power supply MUST be within range of nominal operating voltage ±4%), ▪ Power drop, ▪ Short circuit.; Faulty hydro PCB.; Faulty hydro extension PCB.

Is it safe?

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: no.

Manual reset: Manual reset via user interface. EPRA14~18D + ETSH/X(B)16P30+50E Daikin Altherma 3 H HT ECH₂O 3 | Troubleshooting.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

  • Check the wiring between the hydro PCB and the hydro extension PCB. ; Check if the power supply is compliant with the regulations. ; Perform a check of the hydro PCB. ; Perform a check of the hydro extension PCB.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

What you might notice

What owners and engineers report

13 owner and engineer reports mention this.

  • No heating on the Altherma: 7 reports
  • Controller / thermostat problem on the Altherma: 6 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026