8H on a Daikin Altherma LT: Outlet water temperature too high
Short answer
On a Daikin heat pump, 8H means: Outlet water temperature too high. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Outlet water temperature too high.
Part involved: water circuit temperature protection.
When it shows: The error is generated in case the outlet water temperature is higher than 65°C.
Likely causes:
- Malfunction of the outlet water thermistor [R2T]; Malfunction of the backup heater relays [K1M, K2M]; In case of combination with boiler; Incorrect cooperation of systems.
Is it safe?
| Does the heat pump stop? | Not stated |
|---|---|
| Engineer needed? | Yes |
The manual does not say whether the heat pump stops.
Resetting itself: unknown.
Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).
What you can check
- Read the full error code shown on the user interface and note it, with the date/time, for your installer.
- Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).
What the engineer will check
- Follow the service-manual troubleshooting flow chart for this code: check malfunction of the outlet water thermistor [R2T]; check malfunction of the backup heater relays [K1M, K2M]; check in case of combination with boiler; check incorrect cooperation of systems.
Who to ask for: Heat pump installer / heating engineer.
Certification: None specific for water-side checks; MCS-certified installer recommended.
What you might notice
What owners and engineers report
1 owner and engineer report mentions this.
- No heating on the Altherma LT (low temperature split): 1 report
Sources
- Service Manual ALTHERMA ERHQ006~008BAV3 / ERLQ006~008BAV3(9) / EKHBH(X)008BA (ESIE10-02) ↗ · ESIE10-02 · page 155 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026