81 on a Daikin Altherma LT: Outlet water temperature thermistor abnormality
Short answer
On a Daikin heat pump, 81 means: Outlet water temperature thermistor abnormality. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Outlet water temperature thermistor abnormality.
Part involved: water circuit temperature protection.
When it shows: When the thermistor input is more than 4.96 V or less than 0.04 V during compressor operation*. * (reference) When above about 212°C (less than 120 ohms) or below about –50°C (more than 1,860 kohms). Note: The values vary slightly in some models.
Likely causes:
- Faulty connector connection; Faulty thermistor; Faulty PCB.
Is it safe?
| Does the heat pump stop? | Not stated |
|---|---|
| Engineer needed? | Yes |
The manual does not say whether the heat pump stops.
Resetting itself: unknown.
Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).
What you can check
- Read the full error code shown on the user interface and note it, with the date/time, for your installer.
- Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).
What the engineer will check
- Follow the service-manual troubleshooting flow chart for this code: check faulty connector connection; check faulty thermistor; check faulty PCB.
Who to ask for: Heat pump installer / heating engineer.
Certification: None specific for water-side checks; MCS-certified installer recommended.
What you might notice
What owners and engineers report
1 owner and engineer report mentions this.
- No heating on the Altherma LT (low temperature split): 1 report
Sources
- Service Manual ALTHERMA ERHQ006~008BAV3 / ERLQ006~008BAV3(9) / EKHBH(X)008BA (ESIE10-02) ↗ · ESIE10-02 · page 150 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026