Heat pumps · Error codes · Daikin
UFDaikin

UF on a Daikin heat pump: Code shown on the remote controller for the installation error(s): Stop valve left closed; incorrect interconnections between units (piping and wiring inconsistent); refrigerant overcharge (Flex outdoor installation manual, test-operation table)

Short answer

On a Daikin heat pump, UF means: Code shown on the remote controller for the installation error(s): Stop valve left closed; incorrect interconnections between units (piping and wiring inconsistent); refrigerant overcharge (Flex outdoor installation manual, test-operation table). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma Flex Type

The manual says: Code shown on the remote controller for the installation error(s): Stop valve left closed; incorrect interconnections between units (piping and wiring inconsistent); refrigerant overcharge (Flex outdoor installation manual, test-operation table).

Part involved: inter-unit communication / PCB combination.

When it shows: Detected during test operation / normal operation after installation errors listed.

Likely causes:

  • Stop valve left closed; incorrect interconnections between units (piping and wiring inconsistent); refrigerant overcharge.

On the Altherma HT (high temperature split)

The manual says: System is not set yet.

Part involved: inter-unit communication / PCB combination.

When it shows: The malfunction is determined as soon as the abnormality afor ementioned is detected through checking the system for any erroneous connection of unit.

Likely causes:

  • Improper connection of transmission wiring between indoor-outdoor unit; QA wiring problem; Defect of indoor unit PC board.

Is it safe?

On the Altherma Flex Type

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: After correcting the abnormality press BS3 RETURN on the outdoor PCB to reset and repeat the test operation (installer only).

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.

What the engineer will check

On the Altherma Flex Type

  • Installer remedial action per manual: open stop valves; correct phase sequence; check power wiring; check piping/wiring consistency; correct refrigerant charge by recalculation; repeat test operation within -20~35 C.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

On the Altherma HT (high temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check improper connection of transmission wiring between indoor-outdoor unit; check qA wiring problem; check defect of indoor unit PC board.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026