U7 on a Daikin heat pump: Malfunction of transmission outdoor unit

Short answer

On a Daikin heat pump, U7 means: Malfunction of transmission outdoor unit. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma HT (high temperature split)

The manual says: Malfunction of transmission outdoor unit.

Part involved: inter-unit communication / PCB combination.

When it shows: When transmission is not carried out no rmally for a certain amount of time.

Likely causes:

  • Improper connection of transmission wiring between outdoor unit and external control adaptor for outdoor unit; Improper cool/heat selection; Improper cool/heat unified address (outdoor unit, external control adaptor for outdoor unit); Defect of outdoor unit PC board (A1P); Defect of external control adaptor for outdoor unit.

On the Altherma LT (low temperature split)

The manual says: Signal transmission error (indoor outdoor unit).

Part involved: inter-unit communication / PCB combination.

When it shows: ■ When the data sent from the PM1 can not be received successively for 9 sec. ■ The abnormality is determined if the above fault conditions occurs once. ■ Fault counter is reset when the data from the PM1 can be successfully received | When the data sent from the PM1 can not be received successively for 9 sec. The abnormality is determined if the above fault conditions occurs once. Fault counter is reset when the data from the PM1 can be successfully received. 3 3.

Likely causes:

  • Defective outdoor unit PCB.

Is it safe?

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Altherma LT (low temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.

What the engineer will check

On the Altherma HT (high temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check improper connection of transmission wiring between outdoor unit and external control adaptor for outdoor unit; check improper cool/heat selection; check improper cool/heat unified address (outdoor unit, external control adaptor for outdoor unit); check defect of outdoor unit PC board (A1P); check defect of external control adaptor for outdoor unit.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

On the Altherma LT (low temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check defective outdoor unit PCB.

Who to ask for: Heat pump installer (Daikin-trained).

Certification: None specific; MCS-certified installer recommended.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026