L5 on a Daikin heat pump: Inverter compressor abnormal

Short answer

On a Daikin heat pump, L5 means: Inverter compressor abnormal. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma HT (high temperature split)

The manual says: Inverter compressor abnormal.

Part involved: compressor / inverter drive.

When it shows: When an excessive current flows in the power transistor. (Instantaneous overcurrent al so causes activation.).

Likely causes:

  • Defect of compressor coil (disconnected, defective insulation); Compressor start-up malfunction (mechanical lock); Defect of inverter PC board (A2P); Overcurrent; Overcurrent immediate; Defect of inverter PC board [A4P (1 ø) or A5P (3ø)].

On the Altherma LT (low temperature split)

The manual says: Output over current (inverter PCB).

Part involved: power supply / inverter electrical.

When it shows: ■ A position signal error occurs while the compressor is running. ■ A speed error occurs while the compressor is running. ■ An output over-current input is fed from the output over-current detection circuit to the microcomputer. ■ The system will be shut down if the error occurs 16 times. ■ Clearing condition: Continuous run for about 5 minutes (normal) | A position signal error occurs while the compressor is running. A speed error occurs while the compressor is running. An output over-current input is fed from the output over-current detection circuit to the 3 3 microcomputer. The system will be shut down if the error occurs 16 times. Clearing condition: Continuous run for about 5 minutes (normal).

Likely causes:

  • Over-current due to defective power transistor; Over-current due to wrong internal wiring; Over-current due to abnormal supply voltage; Over-current due to defective PCB; Error detection due to defective PCB; Over-current due to closed stop valve; Over-current due to compressor failure; Over-current due to poor installation condition.

Is it safe?

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Altherma LT (low temperature split)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.

What the engineer will check

On the Altherma HT (high temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check defect of compressor coil (disconnected, defective insulation); check compressor start-up malfunction (mechanical lock); check defect of inverter PC board (A2P); check overcurrent; check overcurrent immediate; check defect of inverter PC board [A4P (1 ø) or A5P (3ø)].

Who to ask for: F-gas certified heat pump engineer with electrical competence.

Certification: UK F-gas certification if the refrigerant circuit is opened; electrical competence (BS 7671) for inverter/PCB work.

On the Altherma LT (low temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check over-current due to defective power transistor; check over-current due to wrong internal wiring; check over-current due to abnormal supply voltage; check over-current due to defective PCB; check error detection due to defective PCB; check over-current due to closed stop valve.

Who to ask for: Heat pump engineer / qualified electrician.

Certification: Electrical competence to BS 7671 (Part P where applicable) for mains supply work.

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • No heating on the Altherma LT (low temperature split): 1 report
  • Heat pump will not start on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.