89-03 on a Daikin heat pump: Heat exchanger freeze-up protection activated during defrost (warning)

Short answer

On a Daikin heat pump, 89-03 means: Heat exchanger freeze-up protection activated during defrost (warning). The heat pump keeps running. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma

The manual says: Heat exchanger freeze-up protection activated during defrost (warning).

Part involved: plate heat exchanger freeze protection.

When it shows: Evaporation temperature is too low during defrost. Outlet water after heat exchanger thermistor <6°C during defrost.

Likely causes:

  • Faulty outlet water after heat exchanger thermistor.; Faulty hydro PCB.

On the Altherma 4 H (R-290)

The manual says: Interruption defrost due to low water volume.

Part involved: plate heat exchanger freeze protection.

When it shows: Plate heat exchanger freeze-up protection activated during defrost on the emitter circuit (auto retry).

Is it safe?

On the Altherma

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: yes.

Manual reset: Automatic reset.

On the Altherma 4 H (R-290)

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Automatic.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check the heating-system water pressure reading on the gauge/display: Daikin operation manuals ask users to check it is above 1 bar. If it is below that, report it to your installer (do not open the unit).
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).
  • Daikin documents this code as resetting automatically once the condition clears; if it keeps coming back, contact your installer.
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

On the Altherma

  • Perform a check of the outlet water after heat exchanger thermistor. . ; Perform a check of the hydro PCB. .

Who to ask for: Heat pump installer / heating engineer.

Certification: None specific for water-side checks; MCS-certified installer recommended.

On the Altherma 4 H (R-290)

  • See Daikin service manual for this generation (not public).

Who to ask for: Heat pump installer / heating engineer.

Certification: None specific for water-side checks; MCS-certified installer recommended.

What you might notice

What owners and engineers report

14 owner and engineer reports mention this.

  • No heating on the Altherma: 7 reports
  • Keeps stopping / cutting out on the Altherma: 2 reports
  • No hot water on the Altherma: 2 reports
  • Stops working in very cold weather on the Altherma: 2 reports
  • Frequent defrosting on the Altherma: 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026