EA on a Daikin Altherma LT: Heating / Cooling switching failure

Short answer

On a Daikin heat pump, EA means: Heating / Cooling switching failure. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Heating / Cooling switching failure.

Part involved: refrigerant circuit / pressure protection.

When it shows: A following condition continues over 10 minute after operating 5 minutes. ■ Cooling (Outlet water temperature – hydro-box heat exchanger temperature) < -10°C ■ Heating (Hydro-box heat exchanger temperature – Outlet water temperature) < -10°C | A following condition continues over 10 minute after operating 5 minutes. Cooling (Outlet water temperature – hydro-box heat exchanger temperature) < -10°C 3 3 Heating (Hydro-box heat exchanger temperature – Outlet water temperature) < -10°C.

Likely causes:

  • Connector in poor contact; Thermistor defective; Outdoor unit PCB defective; Four way valve coil or harness defective; Four way valve defective; Foreign substance mixed in refrigerant; Insufficient gas.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).

What the engineer will check

  • Follow the service-manual troubleshooting flow chart for this code: check connector in poor contact; check thermistor defective; check outdoor unit PCB defective; check four way valve coil or harness defective; check four way valve defective; check foreign substance mixed in refrigerant.

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026