L3 on a Daikin Altherma LT: Switch box temperature rise

Short answer

On a Daikin heat pump, L3 means: Switch box temperature rise. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Switch box temperature rise.

Part involved: inverter PCB thermal protection.

When it shows: With the compressor off, the radiation fin temperature is above 95°C. (Reset is made when the temperature drops below 80°C.) | With the compressor off, the radiation fin temperature is above 95°C. (Reset is made when the temperature drops below 80°C.) 3 3.

Likely causes:

  • Fin temperature rise due to defective outdoor unit fan; Fin temperature rise due to short-circuit; Fin thermistor defective; Connector in poor contact; Outdoor unit PCB defective.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).

What the engineer will check

  • Follow the service-manual troubleshooting flow chart for this code: check fin temperature rise due to defective outdoor unit fan; check fin temperature rise due to short-circuit; check fin thermistor defective; check connector in poor contact; check outdoor unit PCB defective.

Who to ask for: F-gas certified heat pump engineer with electrical competence.

Certification: UK F-gas certification if the refrigerant circuit is opened; electrical competence (BS 7671) for inverter/PCB work.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.