EA-00 on a Daikin Altherma: OU: Cool/heat switchover problem

Short answer

On a Daikin heat pump, EA-00 means: OU: Cool/heat switchover problem. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: OU: Cool/heat switchover problem.

Part involved: refrigerant circuit / pressure protection.

When it shows: Room thermistor is NOT functioning within operation range.

Likely causes:

  • Faulty 4‑way valve.; Faulty main PCB.; Faulty room thermistor.; Faulty wiring between the remote controller and the unit.; Faulty hydro PCB.; Closed stop valve in the refrigerant circuit.; Clogged refrigerant circuit.; Refrigerant overcharge or shortage.; Non‑condensables and/or humidity in the refrigerant circuit.

Is it safe?

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: yes.

Manual reset: Automatic reset after a continuous operation for some time. Manual reset via user interface.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Look at the outdoor unit from outside: check the air inlet/outlet and fan grille are not blocked by leaves, debris, snow or heavy ice build-up (do not remove panels or touch the fan).
  • Daikin documents this code as resetting automatically once the condition clears; if it keeps coming back, contact your installer.
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.
  • If heating/hot water has stopped, the operation manual lets the user confirm on the Malfunctioning screen whether the backup/booster heater may take over as emergency heating (much higher running cost) until the installer attends.

What the engineer will check

  • Perform a check of the 4‑way valve. . ; Perform a check of the main PCB. . ; Perform a check of the room thermistor: ▪ Measure the room temperature and compare to the room temperature shown on the user interface (remote controller). ▪ If temperature shown on the user interface differs from the measured temperature, replace the user interface (remote controller). See documentation of the user interface (remote controller) for more information. ; Check the communication wiring between the remote controller and the unit. . ; Perform a check of the hydro PCB. . ; Check that all stop valves of the refrigerant circuit are open. . ; Check if the refrigerant circuit is clogged. . ; | Troubleshooting ; Check if the refrigerant circuit is correctly charged. . ; Check for the presence of non‑condensables and/or humidity in the refrigerant circuit. .

Who to ask for: F-gas certified heat pump engineer (Daikin-trained installer / Stand By Me partner).

Certification: UK F-gas certification (Category I) for refrigerant circuit work; R-290 (Altherma 4) also needs flammable-refrigerant/hydrocarbon competence.

What you might notice

What owners and engineers report

11 owner and engineer reports mention this.

  • No heating on the Altherma: 7 reports
  • Keeps stopping / cutting out on the Altherma: 2 reports
  • No hot water on the Altherma: 2 reports