E6 on a Daikin heat pump: Standard compressor lock or over current

Short answer

On a Daikin heat pump, E6 means: Standard compressor lock or over current. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma HT (high temperature split)

The manual says: Standard compressor lock or over current.

Part involved: compressor / inverter drive.

On the Altherma LT (low temperature split)

The manual says: Compressor lock.

Part involved: compressor / inverter drive.

When it shows: ■ Judging from current waveform generated when high-frequency voltage is applied to the compressor. ■ The system will be shut down if the error occurs 16 times. ■ Clearing condition: Continuous run for about 5 minutes (normal) | Judging from current waveform generated when high-frequency voltage is applied to the compressor. The system will be shut down if the error occurs 16 times. 3 3 Clearing condition: Continuous run for about 5 minutes (normal).

Likely causes:

  • Compressor locked.

Is it safe?

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Altherma LT (low temperature split)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.

What the engineer will check

On the Altherma HT (high temperature split)

  • See Daikin service manual for this generation.

Who to ask for: F-gas certified heat pump engineer with electrical competence.

Certification: UK F-gas certification if the refrigerant circuit is opened; electrical competence (BS 7671) for inverter/PCB work.

On the Altherma LT (low temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check compressor locked.

Who to ask for: F-gas certified heat pump engineer with electrical competence.

Certification: UK F-gas certification if the refrigerant circuit is opened; electrical competence (BS 7671) for inverter/PCB work.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026