H6 on a Daikin Altherma LT: Compressor start up failure

Short answer

On a Daikin heat pump, H6 means: Compressor start up failure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Compressor start up failure.

Part involved: compressor / inverter drive.

When it shows: ■ The compressor fails to start in about 15 seconds after the compressor run command signal is sent. ■ Clearing condition: Continuous run for about 5 minutes (normal) ■ The system will be shut down if the error occurs 8 times | The compressor fails to start in about 15 seconds after the compressor run command signal is sent. Clearing condition: Continuous run for about 5 minutes (normal) 3 3 The system will be shut down if the error occurs 8 times.

Likely causes:

  • Compressor relay cable disconnected; Compressor itself defective; Outdoor unit PCB defective; Stop valve closed; Input voltage out of specification.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.

What the engineer will check

  • Follow the service-manual troubleshooting flow chart for this code: check compressor relay cable disconnected; check compressor itself defective; check outdoor unit PCB defective; check stop valve closed; check input voltage out of specification.

Who to ask for: F-gas certified heat pump engineer with electrical competence.

Certification: UK F-gas certification if the refrigerant circuit is opened; electrical competence (BS 7671) for inverter/PCB work.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026