Heat pumps
Heat pumps · Error codes · Daikin
H8Daikin · Altherma LT (low temperature split)

H8 on a Daikin Altherma LT: CT or related abnormality

Short answer

On a Daikin heat pump, H8 means: CT or related abnormality. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: CT or related abnormality.

Part involved: compressor / inverter drive.

When it shows: The compressor running frequency is below 55 Hz and the CT input is below 0.1 V. (The input current is also below 0.5 A.) ■ If this error repeats 4 times, the system will be shut down. ■ The error counter will reset itself if this or any other error does not occur during the following 60-minute compressor running time (total time) | The compressor running frequency is below 55 Hz and the CT input is below 0.1 V. (The input current is also below 0.5 A.) If this error repeats 4 times, the system will be shut down. 3 3 The error counter will reset itself if this or any other error does not occur during the following 60-minute compressor running time (total time).

Likely causes:

  • Power transistor defective; Internal wiring broken or in poor contact; Reactor defective; Outdoor unit PCB defective.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.

What the engineer will check

  • Follow the service-manual troubleshooting flow chart for this code: check power transistor defective; check internal wiring broken or in poor contact; check reactor defective; check outdoor unit PCB defective.

Who to ask for: F-gas certified heat pump engineer with electrical competence.

Certification: UK F-gas certification if the refrigerant circuit is opened; electrical competence (BS 7671) for inverter/PCB work.

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • No heating on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026