Heat pumps · Error codes · Daikin
U2Daikin

U2 on a Daikin heat pump: Power supply insufficient or instantaneous failure

Short answer

On a Daikin heat pump, U2 means: Power supply insufficient or instantaneous failure. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Altherma HT (high temperature split)

The manual says: Power supply insufficient or instantaneous failure.

Part involved: power supply / inverter electrical.

When it shows: When the abnormal voltage of main circuit capacitor built in the inverter and abnormal power supply voltage are detected.

Likely causes:

  • Power supply insufficient; Instantaneous power failure; Defect of outdoor inverter PC board (A2P) ESIE09-08C; Defect of indoor inverter PC board [A4P (1 ø) or A5P (3ø)]; Converting problem Warning: CAPACITOR SHOCK HAZARD. The capac itors (top surfaces) can hold up to 220V. Use correct precautions when servicing. ESIE09-08C.

On the Altherma LT (low temperature split)

The manual says: Low-voltage or over-voltage detection.

Part involved: power supply / inverter electrical.

When it shows: ■ An over-voltage signal is fed from the over-voltage detection circuit to the microcomputer, or the voltage being detected by the DC voltage detection circuit is judged to be below 150 V for 0.1 second. ■ The system will be shut down if the error occurs 16 times. ■ Clearing condition: Continuous run for about 60 minutes (normal) | An over-voltage signal is fed from the over-voltage detection circuit to the microcomputer, or the voltage being detected by the DC voltage detection circuit is judged to be below 150 V for 0.1 second. The system will be shut down if the error occurs 16 times. Clearing condition: Continuous run for about 60 minutes (normal) Supply voltage not as specified Over-voltage detector or DC voltage detection circuit defective PAM control part(s) defective.

Likely causes:

  • Supply voltage not as specified; Over-voltage detector or DC voltage detection circuit defective; PAM control part(s) defective.

Is it safe?

On the Altherma HT (high temperature split)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

On the Altherma LT (low temperature split)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Reset via the remote controller (Inspection/Test button) after the cause is fixed; some codes need a manual reset of the remote-controller memory (service manual section 1.4).

What you can check

  • Read the full error code shown on the user interface and note it, with the date/time, for your installer.
  • Check the heat pump isolator switch(es) and the consumer-unit breaker/RCD for the heat pump are ON. If a breaker or RCD has tripped, do not keep resetting it - leave it and call an engineer.

What the engineer will check

On the Altherma HT (high temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check power supply insufficient; check instantaneous power failure; check defect of outdoor inverter PC board (A2P) ESIE09-08C; check defect of indoor inverter PC board [A4P (1 ø) or A5P (3ø)]; check converting problem Warning: CAPACITOR SHOCK HAZARD. The capac itors (top surfaces) can hold up to 220V. Use correct precautions when servicing. ESIE09-08C.

Who to ask for: Heat pump engineer / qualified electrician.

Certification: Electrical competence to BS 7671 (Part P where applicable) for mains supply work.

On the Altherma LT (low temperature split)

  • Follow the service-manual troubleshooting flow chart for this code: check supply voltage not as specified; check over-voltage detector or DC voltage detection circuit defective; check pAM control part(s) defective.

Who to ask for: Heat pump engineer / qualified electrician.

Certification: Electrical competence to BS 7671 (Part P where applicable) for mains supply work.

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • No heating on the Altherma LT (low temperature split): 1 report
  • Heat pump will not start on the Altherma LT (low temperature split): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026