AH-00 on a Daikin Altherma: Tank disinfection function not completed correctly

Short answer

On a Daikin heat pump, AH-00 means: Tank disinfection function not completed correctly. The heat pump keeps running.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Tank disinfection function not completed correctly.

Part involved: tank disinfection function.

When it shows: Disinfection setpoint is NOT reached within 6 hours or NOT kept for the required time.

Likely causes:

  • Large quantity of hot water has been tapped during/before disinfection.; ▪ Backup heater is restricted during disinfection, ▪ Backup heater NOT allowed.; Faulty booster heater settings.

Is it safe?

Does the heat pump stop?No
SeverityWarning

The heat pump keeps running.

Resetting itself: yes.

Manual reset: Automatic reset when disinfection is completed.

What you can check

  • Read the full error code and sub-code shown on the user interface (Malfunctioning screen; press the help button for Daikin's long description) and note it, with the date/time, for your installer.
  • Check the domestic hot water / programme schedule and settings on the user interface (Daikin notes AH-00 can be caused by large hot-water draws or stopping the tank during disinfection).
  • Daikin documents this code as resetting automatically once the condition clears; if it keeps coming back, contact your installer.
  • Do NOT bleed radiators while an error/malfunction symbol is displayed: Daikin operation manuals warn refrigerant may have leaked into the water circuit - ventilate and call your installer.

What the engineer will check

  • hours or NOT kept for the required time. Unit will NOT stop operating. Automatic reset when disinfection is completed. ; Check when the disinfection is scheduled. Schedule it when there is little chance that water will be tapped so that the disinfection can finish in time. ; Check the backup heater settings [2‑00] to [2‑04] and [4‑00]. . ; Check the domestic hot water tank and booster heater related settings. . ; | Troubleshooting.

Who to ask for: Heat pump installer / heating engineer.

Certification: G3 unvented hot water competence for cylinder safety components.

What you might notice

What owners and engineers report

5 owner and engineer reports mention this.

  • Hot water not hot enough on the Altherma: 5 reports

Sources

A code explains what the controller detected, not a confirmed root cause.