Inverter and battery codes from the manufacturers’ own manuals, with the few checks a homeowner can safely make — and the codes whose online meanings are wrong.
Code lists by brand
984 solar and battery codes from more than 25 brands' manuals are in the database. Homeowners may read the code, check the AC isolator and consumer-unit breaker are on, check the app and Wi-Fi, and restart the way the manual allows — never open enclosures or touch DC wiring.
No. Solarbank units contain batteries, and the UK Solarbank 4 E5000 Pro can charge from the grid at 2,500 W, so they are outside the GB plug-in…
Read the answer →02On an Anker SOLIX Solarbank a flashing red power-button light signals a malfunction or warning. Anker's manual gives no code table, so open the…
Read the answer →03No. A portable power station such as the BLUETTI AC180 is a battery that powers appliances from its own sockets; it does not feed your home…
Read the answer →04A red light on an EcoFlow STREAM Ultra, AC Pro or STREAM Microinverter means the device has detected a fault. EcoFlow does not print error codes…
Read the answer →05Since 27 August 2026 GB law allows plug-in solar only for solar-only devices up to 800 W AC that are not designed to store imported electricity.…
Read the answer →06An EcoFlow STREAM or PowerOcean unit showing offline usually has lost Wi-Fi or cloud connection rather than stopped working. Check the device's…
Read the answer →07Enphase 'AC Voltage Out Of Range' means the microinverters saw grid voltage outside their permitted range and stopped exporting until it…
Read the answer →08A solid red status LED on an Enphase IQ8 means 'DC Resistance Low - Power Off': insulation between the panel wiring and earth fell below about 7…
Read the answer →09Enphase 'DC Voltage Too Low' means a microinverter is getting too little voltage from its panel. It's normal at dawn, dusk and in dull spells. If…
Read the answer →10'Not reporting' usually means the IQ Gateway (Envoy) has lost internet, not that the panels stopped. Check the gateway's network LED (solid green…
Read the answer →11Fronius GEN24 and GEN24 Plus inverters show four-digit status codes in Solar.web under Service Messages and in the inverter's web interface Event…
Read the answer →12Fronius State 306 (low PV output) and 307 (low PV voltage) mean there isn't enough power or voltage from the panels to feed the grid. Fronius says…
Read the answer →13Fronius State 509 means the inverter hasn't fed any energy into the grid in the past 24 hours. Snow, dirt or a long dull spell are typical causes.…
Read the answer →14Fronius class 1 codes come from the public grid, not the inverter: 102 means AC voltage too high, 103 too low, 105 and 106 frequency out of range,…
Read the answer →15Fronius codes 447 and 475 (insulation fault between the panels and earth) stop feed-in, while 502 is a warning that insulation on the solar…
Read the answer →16On GoodWe ET, ET Plus+ and BT inverters, a steady FAULT LED means a fault has occurred; a FAULT LED blinking once means the backup output is…
Read the answer →17GoodWe 'Isolation Failure' means insulation resistance between the solar DC wiring and earth is too low, often due to damaged cable insulation, a…
Read the answer →18GoodWe error 13 'Over Temperature' means the inverter has been too hot for too long, usually because of high surrounding temperature, poor airflow…
Read the answer →19GoodWe 'Utility Loss' means the inverter can't detect the grid: a power cut, a tripped AC breaker or loose AC connection. It clears automatically…
Read the answer →20Lux Power hybrids show E codes (faults that stop the inverter) and W codes (warnings) on the LCD and in the LuxPower monitoring app. Grid warnings…
Read the answer →21SMA Event 3501 means the inverter has detected an earth (ground) fault in the solar panel wiring, so it stops feeding in. Don't touch the panels,…
Read the answer →22SMA Events 3901 and 3902 mean the panels are not yet producing enough voltage for the inverter to start feeding in. It is normal at dawn, dusk and…
Read the answer →23SMA 'Grid incident' events mean grid voltage or frequency went outside the permitted limits, so the inverter disconnected: 101-105 and 301 for…
Read the answer →24SMA Event 6501 means the inverter switched off because it got too hot; Event 8003 means it reduced power for more than ten minutes because of…
Read the answer →25A red LED on an SMA Sunny Boy means an event has occurred. Open the SMA Energy app, Sunny Portal (ennexOS) or the inverter's web interface to read…
Read the answer →26On a SOFAR HYD-ES, ID01 GridOVP means grid voltage too high, ID02 too low, ID03 GridOFP frequency too high and ID04 too low. If occasional, the…
Read the answer →27SOFAR ID56 PvIsoFault (ID042 IsoFault on HYD-EP models) means insulation resistance between the solar panels and earth is too low, usually from…
Read the answer →28For many SOFAR internal faults (for example HYD-ES ID09-ID12 and ID17-ID26), the manual's remedy is to switch the inverter off, wait five minutes…
Read the answer →29Victron SmartSolar and BlueSolar chargers show 'Err' numbers in VictronConnect and VRM. Many reset themselves: Err 1 battery hot, Err 2 battery…
Read the answer →30On the Zendure Hyper 2000, yellow lights mean something is disconnected: left solid, low battery and not charging; left blinking, battery not…
Read the answer →31Not under the plug-in route. SolarFlow systems include batteries, and models such as the Hyper 2000 and 2400 AC can charge from the grid, so they…
Read the answer →32eddi fault codes point to the immersion side: (4)1 heater load above 16 A, (4)2 overheating, (4)3 no signal from the harvi, (4)4 grid sensor…
Read the answer →33It means the Fox ESS inverter can no longer see mains power, usually because of a power cut or because its AC isolator or consumer-unit breaker is…
Read the answer →34Both mean mains voltage went outside the limits the inverter must obey under UK grid rules; 10min Volt Fault uses a ten-minute average. Fox says…
Read the answer →35Iso Fault means the inverter measured low insulation between the solar panel wiring and earth, often from water ingress or damaged cable. It will…
Read the answer →36Only in a limited way. Many Fox ESS alarms say 'Disconnect PV, grid and battery, then reconnect', which means isolating DC and battery circuits -…
Read the answer →37Error 200 is an arc-fault (AFCI) trip: the inverter has detected an electric arc in the solar wiring. Growatt says it then shuts down permanently.…
Read the answer →38Error 203 means low insulation resistance between the PV wiring and earth. Growatt's MIN manual gives a threshold of more than 25 kΩ, or 500 kΩ…
Read the answer →39Error 302 means the Growatt inverter cannot see the grid. The usual causes are a power cut, a tripped or switched-off AC breaker or isolator, or…
Read the answer →40Alarm 2032 means the SUN2000 inverter lost the mains grid: a power cut, or the AC circuit disconnected or its breaker switched off. It is a major…
Read the answer →412034 means mains voltage was above the inverter's protection threshold, so it disconnected. Occasional alarms recover automatically. If frequent,…
Read the answer →42Alarm 2062 means the inverter measured a short or poor insulation between the PV array and earth, often from damp or damaged cabling. The inverter…
Read the answer →432064 is an unrecoverable internal circuit fault (cause IDs 1-12 cover boost, control, residual-current sensor, EEPROM, relay and DC bus faults).…
Read the answer →44The SolarVault 3 manual lists codes F0, F1, F2 and E1 to E7 with fixes but no fault names. F0 points to temperature or low charge. F1 to E5 just…
Read the answer →45'Grid CT Lost' means the device has lost its reading of power at your meter, usually because the wireless harvi dropped out. Charging or diverting…
Read the answer →46myenergi devices only use 2.4 GHz Wi-Fi. Check the device's time, date and time zone, the router's 2.4 GHz band, signal strength at the device and…
Read the answer →47myenergi devices warn when supply voltage leaves the allowed range; myenergi uses 253 V as the upper limit. On sunny days solar export can raise…
Read the answer →48In SolarEdge's own January 2026 error list, 3x9A means the inverter has locked itself, either manually or because a safety feature tripped. It is…
Read the answer →49Codes such as 2x1F, 2x21 or 18x1F mean the grid voltage measured at the inverter is above the UK limit it has been set to. On sunny middays,…
Read the answer →50At each start-up, a SolarEdge inverter checks the insulation between the panels' wiring and earth. It trips if the reading falls below 600 kΩ on…
Read the answer →513x6E means the inverter has lost communication with the SolarEdge Energy Meter. Without that meter, it cannot measure consumption, enforce an…
Read the answer →52SolarEdge grid-voltage, grid-frequency and grid-down codes (2x1F, 2x20, 2x28 and 18x40 upwards) clear once the grid is back within limits. Night…
Read the answer →53IE 13 on an X1-Hybrid G4, or IE:00020 IsoFault on an X1-Mini or Boost G4, means the inverter has measured low insulation between the solar wiring…
Read the answer →54On the Pocket WiFi V4, a flashing red light means the dongle can't talk to the inverter. A steady red light means it can't join your router.…
Read the answer →55On an X1-Hybrid G4, grid codes (IE 02, 03, 04, 08) clear themselves once the grid is normal. For overloads such as IE 16 or IE 17, the manual lets…
Read the answer →56It is a UK export-limitation alarm under ENA G100: exported current exceeded the configured backflow limit. G100 requires a manual reset, which…
Read the answer →57NO-Grid means the Solis inverter cannot detect mains voltage, so it has stopped generating. The usual causes are a power cut or the inverter's AC…
Read the answer →58OV-G-V01 means mains voltage exceeded the inverter's upper limit, so it disconnected. Occasional events clear automatically. If it happens often…
Read the answer →59PV ISO-PRO01/02 means the inverter detected low insulation between the panel wiring and earth. Solis says if it only happens on rainy days or…
Read the answer →60Yes, broadly. Sunsynk hybrids are built on Deye hardware, and Deye's SUN-SG04LP1-EU manual (April 2026) uses the same F-code numbers and meanings…
Read the answer →61F13 means the working mode changed: the grid type or frequency changed, the battery was set to 'No battery', or older firmware logged a work-mode…
Read the answer →62They are grid protection codes: F35 no grid (power cut or tripped supply), F42/F44 low voltage, F43 high voltage, F47 over-frequency and F48…
Read the answer →