What is 'State 2 excursion' on a Solis inverter?
Short answer
It is a UK export-limitation alarm under ENA G100: exported current exceeded the configured backflow limit. G100 requires a manual reset, which Solis puts under Settings > EPM Setting > Built-in EPM Setting > G100V2 Alarm Clear (S6 string manual V1.1, 04/2024, checked 24 September 2026). Your installer should reset it and find why the limit was breached.
Last checked 24 September 2026 · 1 source
In more detail
- Common causes: CT clamp position/direction, meter comms (Fail Safe 2010H), limit settings.
- Only applies to systems with an export limit.
The facts, dated
- 01Solis: 'As required by G100, State 2 excursion alarm should be manually reset.'
standard · UK · checked 24 September 2026 · solisinverters.com