8 codes

CodeMeaningStops?Homeowner check?
Data Point was not created recently
Latest datapoint old - ensure the dongle shows a solid blue light and has a stable internet connection.
NoYes
ELECTRICITY_METER_COM_FAIL
Electricity meter communication failure - ensure meter communications are stable and connected into the correct socket on the underside of the inverter.
PartlyYes
Grid voltage Too High
Grid voltage too high - ensure the AC isolator is on and AC connections are tight; if connections are good contact the local DNO.
YesYes
Grid voltage Too Low
Grid voltage too low - ensure the AC isolator is on and AC connections are tight; if good contact the local DNO.
YesYes
INV_GFCI_FAULT
GFCI (earth leakage) fault - make sure that there is no DC voltage to earth.
YesYes
INV_NO_UTILITY
No utility (grid) detected - ensure the AC supply is switched on and the AC connections are tight and sound.
YesYes
INV_PV_OVER_VOLTAGE
PV over-voltage - check that the string voltage does not exceed 580 VDC.
YesYes
Meters enabled but not being read
Meters enabled but not being read - ensure meter comms are stable and in the correct socket.
PartlyYes