Why is one Enphase microinverter showing a solid red light?

Short answer

A solid red status LED on an Enphase IQ8 means 'DC Resistance Low - Power Off': insulation between the panel wiring and earth fell below about 7 kΩ, so that microinverter stopped; the rest keeps working. The fault stays latched until your installer clears it remotely through the Enphase Installer Platform; if it returns, the panel or microinverter needs replacing.

Last checked 24 September 2026 · 1 source

In more detail

  • Causes: module insulation defect, damaged wiring/connectors, moisture ingress.
  • Flashing orange = grid OK but no gateway communication; flashing red = grid absent/out of spec.

The facts, dated

  1. 01
    IQ8 DC Resistance Low trips below ~7 kOhm PV-to-earth — 7 kOhm

    manufacturer · n/a · checked 24 September 2026 · midsummerwholesale.co.uk