CodeMeaningStops?Homeowner check?
CT LN Reversed
CT LN Reversed - L and N of SP-CT reversed / SP-CT PE wire.
PartlyYes
Error 200
AFCI fault - an electric arc occurred in the PV system; AFCI tripped and the inverter is in permanent shutdown.
YesYes
Error 201
Residual I High - leakage current too high.
YesYes
Error 202
PV Voltage High - the DC input voltage is exceeding the maximum tolerable value.
YesYes
Error 203
PV Isolation Low - insulation problem.
YesYes
Error 300
AC V Outrange - utility grid voltage is out of permissible range.
YesYes
Error 302
No AC connection.
YesYes
Error 303
PE abnormal - voltage of Neutral and PE above 30 V.
YesYes
Error 304
AC F Outrange - utility grid frequency out of permissible range.
YesYes
Error 402
Output High DCI.
YesYes
Error 404
Bus sample fault.
YesYes
Error 405
Relay fault.
YesYes
Error 407
Auto Test Failed - auto test didn't pass.
YesYes
Error 408
Over Temperature.
PartlyYes
Error 409
Bus over voltage.
YesYes
Error 411
DSP communicates with M3 abnormal.
YesYes
Error 414
EEPROM fault.
YesYes
Error 417
The data sampled by the DSP and redundant M3 is not the same.
YesYes
Error 420
GFCI fault.
YesYes
Error 425
AFCI self-test fault.
YesYes
PairingTime Out
Communication fault between SP-CT and inverter (distance/pairing).
PartlyYes
Warning 202
DC SPD function abnormal.
YesYes
Warning 203
PV1 or PV2 circuit short.
YesYes
Warning 401
Inverter communicates with Meter abnormal.
PartlyYes
Warning 404
EEPROM abnormal.
YesYes
Warning 405
Firmware version is not consistent.
YesYes