Solar · Error codes · Growatt
Error 304Growatt

Error 304 on a Growatt inverter: AC F Outrange - utility grid frequency out of permissible range

Short answer

On a Growatt inverter, Error 304 means: AC F Outrange - utility grid frequency out of permissible range. The inverter stops until the fault clears or is reset. The wording differs by model range — each is shown below.

Reviewed 24 September 2026 · 2 sources

What it means

On the MIN 2500-6000TL-X

The manual says: AC F Outrange - utility grid frequency out of permissible range.

Part involved: AC grid protection (frequency).

Likely causes:

  • Grid frequency.

On the SPH 3000-6000TL BL-UP (48 V battery hybrid)

The manual says: AC F Outrange - grid frequency fault.

Part involved: AC grid protection (frequency).

Likely causes:

  • grid frequency fault.

Is it safe?

Does the inverter stop?Yes
SeverityFault — clears by itself when the condition goes

The inverter stops until the fault clears or is reset.

Resetting itself: yes - reconnects when frequency is back within limits.

Manual reset: no.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Usually a brief grid disturbance; no action if it clears the same day.
  • Check the solar/battery AC isolator and the consumer-unit breaker/RCD are ON (do not reset a breaker that trips again immediately).
  • Growatt's manual says 'restart inverter'. A homeowner can switch the inverter off and on at its AC isolator/breaker; leave DC switching to the installer unless the manual step says to switch DC off immediately (Error 202).

What the engineer will check

  • Verify country/grid code (UK G98/G99).
  • Log grid frequency.
  • Check for unstable supply (e.g. generator/backup operation).

Who to ask for: PV installer.

Certification: Usually none (grid-side event). If persistent: installer/electrician to measure supply voltage and check settings; DNO investigates supply voltage (G98/G99 protection settings must not be changed without DNO agreement).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026