Why does my SMA inverter keep showing 'Grid incident'?

Short answer

SMA 'Grid incident' events mean grid voltage or frequency went outside the permitted limits, so the inverter disconnected: 101-105 and 301 for high voltage, 202-206 for no grid or low voltage, 401-503 for frequency. It reconnects automatically. If it keeps happening on sunny days, ask your installer to measure the voltage and raise it with your network operator.

Last checked 24 September 2026 · 1 source

In more detail

  • Only the grid operator can agree changes to protection limits (UK G98/G99).
  • Event 302 'Active power limited AC voltage' is derating, not a stop.

The facts, dated

  1. 01
    SMA Event 301: ten-minute average grid voltage outside permissible range — 301 event

    manufacturer · n/a · checked 24 September 2026 · files.sma.de