Solar · Error codes

Huawei alarm 2062 Low Insulation Resistance - is my system unsafe?

Short answer

Alarm 2062 means the inverter measured a short or poor insulation between the PV array and earth, often from damp or damaged cabling. The inverter will not connect while it persists. FusionSolar shows the measured resistance and a possible fault position. Leave DC wiring alone and have your installer test the strings (SUN2000-L1 manual Issue 06, checked 24 September 2026).

Last checked 24 September 2026 · 1 source

In more detail

  • Damp-weather-only alarms suggest moisture ingress.
  • Installer checks PE cable and each string's impedance to ground.

The facts, dated

  1. 01
    Huawei: app shows 'Current insulation resistance: x MOhm, possible short circuit position: x%'.

    manufacturer · UK · checked 24 September 2026 · solar.huawei.com