Solar · Error codes

SolarEdge inverter error codes

SolarEdge · A major brand in the UK. 75 codes across 2 product families, each taken from the manufacturer’s manuals. SolarEdge technical support ↗

Find a SolarEdge engineer →75 codes · reviewed 24 September 2026

Filter by product family

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

75 codes

CodeMeaningStops?Homeowner check?
2x1A
Faulty AC Relay: Faulty AC relay / relay feedback - contact SolarEdge support (RMA).
YesYes
2x1D
Phase Balance Error: Line to Neutral voltage is above threshold.
YesYes
2x1E
Phase Balance Error: Line to Neutral voltage is below threshold.
YesYes
2x1F
AC Voltage Too High: Grid voltage is above the country limit.
YesYes
2x2
Night mode: Night Mode is an inverter status indicating that the input voltage is below 6 V DC.
YesYes
2x2C
No Country Selected: No country selected - select the country.
YesYes
2x9
AC Current Surge / Ground current surge: Ground current surge.
YesYes
2x10
Hardware Error: Vref1V or Vref2V > +/-3% - contact support (RMA).
YesYes
2x11
Temperature Too High: Over temperature.
PartlyYes
2x18
Faulty Temp. Sensor: Broken or unconnected temperature sensor.
YesYes
2x19
Isolation Fault: PV solar array is not properly isolated from ground earth.
YesYes
2x20
AC Voltage Too Low: Grid voltage is below the country limit.
YesYes
2x21
AC Voltage Too High: Grid voltage is above the country limit.
YesYes
2x22
AC Freq Too High: AC frequency too high.
YesYes
2x23
AC Freq Too Low: AC frequency too low.
YesYes
2x24
DC Injection: DC injection - contact SolarEdge support.
YesYes
2x25
Ground Current - RCD: Ground faults may occur due to insufficient insulation to the ground.
YesYes
2x26
Ground Current - RCD: Ground faults may occur due to insufficient insulation to the ground.
YesYes
2x28
Islanding: Grid is down. When AC grid voltage returns the inverter will restart after the reconnection time.
YesYes
2x29
AC Voltage Too Low: Grid voltage is below the country limit.
YesYes
2x90
Islanding - Passive: Grid is down. When AC grid voltage returns the inverter will restart after the reconnection time.
YesYes
2x95
Power train error: Power train error - contact support (RMA).
YesYes
2x96
Arc Fault Detected: Arc detection / arc fault detected (Arc-DSP).
YesYes
2x97
Arc Fault Detected: Arc detection / arc fault detected (Arc-DSP).
YesYes
2x98
Arc detector self-test failed: Tx test (previously known as arc test error) - arc detector self-test failed.
YesYes
2xA
Ground Current - RCD: Ground faults may occur due to insufficient insulation to the ground.
YesYes
2xB5
Relay feedback: Faulty AC relay / relay feedback - contact SolarEdge support (RMA).
YesYes
2xB6
Temperature Too High: Over temperature.
PartlyYes
2xC5
RSD Error: Rapid Shutdown hardware error / rapid shutdown test failed - check safe DC voltage drops below 30 V.
YesYes
2xD
AC Current Surge / Ground current surge: Ground current surge.
YesYes
2xE
AC Voltage Too High: AC voltage surge.
YesYes
2xF
DC Voltage Too High (surge): The SolarEdge system normally eliminates DC overvoltage errors; if the fault persists check strings.
YesYes
3x6A
The device is locked, due to either human intervention, or automatically due to one or more safety features.
YesYes
3x6D
Internal RGM Error: Internal RGM (revenue-grade meter) error - check the Energy Meter CTs wiring.
PartlyYes
3x6E
Energy Meter Comm. Error: Energy Meter communication error - refer to Energy Meter troubleshooting.
PartlyYes
3x9A
The device is locked, due to either human intervention, or automatically due to one or more safety features.
YesYes
3x11
Arc Fault Detected: Arc detection / arc fault detected (Arc-DSP).
YesYes
3xA7
Country mismatch: Country mismatch - select the country.
YesYes
3xB
No Country Selected: No country selected - select the country.
YesYes
8x1C
AC Voltage Too Low (Line 1): AC voltage too low.
YesYes
8x1F
AC Voltage Too High (Line 1): Grid voltage is above the country limit.
YesYes
8x2B
Ground Current - RCD: Ground faults may occur due to insufficient insulation to the ground.
YesYes
8x2E
AC Freq Too High: AC frequency too high (Line 1).
YesYes
8x10
Communication Error: Communication error - contact SolarEdge support.
YesYes
8x47
Temperature Too High: Over temperature.
PartlyYes
8x58
Isolation Fault: PV solar array is not properly isolated from ground earth.
YesYes
18x1A
AC Voltage Too High: AC voltage surge.
YesYes
18x1B
AC Voltage Too High: AC voltage surge.
YesYes
18x1C
AC Voltage Too Low: Line voltage is low.
YesYes
18x1F
AC Voltage Too High: Grid voltage is above the country limit.
YesYes
18x3
Night mode: Night Mode is an inverter status indicating that the input voltage is below 6 V DC.
YesYes
18x3B
I-ACDC: AC overcurrent (I-ACDC L1/L2/L3); if flagged on all three phases at once, most likely a DC-related issue on site.
YesYes
18x3C
I-ACDC: AC overcurrent (I-ACDC L1/L2/L3); if flagged on all three phases at once, most likely a DC-related issue on site.
YesYes
18x7F
IRCDMax: RCD current surge - ground faults may occur due to insufficient insulation to the ground.
YesYes
18x8E
Arc Fault Detected: Arc detection / arc fault detected (Arc-DSP).
YesYes
18x19
AC Voltage Too High: AC voltage surge.
YesYes
18x20
AC Voltage Too High: Grid voltage is above the country limit.
YesYes
18x21
AC Voltage Too High: Grid voltage is above the country limit.
YesYes
18x39
I-ACDC: AC overcurrent (I-ACDC L1/L2/L3); if flagged on all three phases at once, most likely a DC-related issue on site.
YesYes
18x40
AC Freq Too High: The frequency measured on L1 is higher than the thresholds.
YesYes
18x43
AC Freq Too Low: The frequency measured on L1 is lower than the thresholds.
YesYes
18x60
Islanding Trip1: Grid is down. When AC grid voltage returns the inverter will restart after the reconnection time.
YesYes
18x62
Islanding Trip2: Grid is down. When AC grid voltage returns the inverter will restart after the reconnection time.
YesYes
18x75
Temperature Too High: Over temperature.
PartlyYes
18x76
Temperature Too Low: Make sure the inverter is installed where ambient temperature is within the datasheet range.
YesYes
18x85
Faulty Temp. Sensor: Broken or unconnected temperature sensor.
YesYes
18x86
Isolation Fault: PV solar array is not properly isolated from ground earth.
YesYes
18xA9
RCD Error: RCD sensor error - contact SolarEdge support.
YesYes
18xAB
Over voltage Vin: Over voltage in DC input of the inverter. Check the strings' voltage.
YesYes
18xB5
DC/AC in-stage overvoltage: DC/AC in-stage overvoltage - contact support, RMA related.
YesYes
18xB7
DC/AC in-stage overvoltage: DC/AC in-stage overvoltage - contact support, RMA related.
YesYes
18xC7
RSD Error: Rapid Shutdown hardware error / rapid shutdown test failed - check safe DC voltage drops below 30 V.
YesYes
18xD8
AC Voltage Too High: Grid voltage is above the country limit.
YesYes
18xDB
AC Voltage Too Low: Grid voltage is below the country limit.
YesYes
WARNING 1
Fan Failure - contact support.
NoYes