SolarpunkHomes
Sign inCall us · +44 7510 081687
Solar
Solar · Error codes · SolarEdge
2xB5SolarEdge · HD-Wave single-phase inverter (SE2200H-SE6000H)

2xB5 on a SolarEdge HD-Wave single-phase inverter: Relay feedback: Faulty AC relay / relay feedback - contact SolarEdge support (RMA)

Short answer

On a SolarEdge inverter, 2xB5 means: Relay feedback: Faulty AC relay / relay feedback - contact SolarEdge support (RMA). The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Relay feedback: Faulty AC relay / relay feedback - contact SolarEdge support (RMA).

Part involved: Grid relay / relay test.

Likely causes:

  • Internal AC relay failure.

Is it safe?

Does the inverter stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: may clear at next start if caused by N-PE issue.

Manual reset: installer.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Check the solar/battery AC isolator and the consumer-unit breaker/RCD are ON (do not reset a breaker that trips again immediately).
  • If the code persists, contact the installer. SolarEdge's list says 'OFF/ON to reconnect' for some codes - that means the inverter's own ON/OFF switch; only use it if your installer has shown you how. Never open the inverter or touch DC cables/connectors.

What the engineer will check

  • Check N and PE connections and N-PE voltage.
  • Restart.
  • Replace inverter if relay test keeps failing.

Who to ask for: PV installer / electrician.

Certification: Electrician competent in grid-connected PV (BS 7671 Section 712; IET Code of Practice for Grid-connected Solar PV), ideally the original MCS-certified PV installer; brand-approved/trained installer to keep manufacturer warranty.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026