Solar · Error codes · SolarEdge
3xA7SolarEdge · HD-Wave single-phase inverter (SE2200H-SE6000H)

3xA7 on a SolarEdge HD-Wave single-phase inverter: Country mismatch: Country mismatch - select the country

Short answer

On a SolarEdge inverter, 3xA7 means: Country mismatch: Country mismatch - select the country. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Country mismatch: Country mismatch - select the country.

Part involved: Country / grid-code setting.

Likely causes:

  • Country setting mismatch between boards.

Is it safe?

Does the inverter stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: installer sets the country (UK G98/G99) via SetApp/display.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Contact the installer - common after a board swap or firmware update.
  • If the code persists, contact the installer. SolarEdge's list says 'OFF/ON to reconnect' for some codes - that means the inverter's own ON/OFF switch; only use it if your installer has shown you how. Never open the inverter or touch DC cables/connectors.

What the engineer will check

  • Select correct UK country/grid code.
  • Verify G98/G99 protection settings against the DNO connection agreement.

Who to ask for: PV installer.

Certification: Electrician competent in grid-connected PV (BS 7671 Section 712; IET Code of Practice for Grid-connected Solar PV), ideally the original MCS-certified PV installer; brand-approved/trained installer to keep manufacturer warranty.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026