SolarpunkHomes
Sign inCall us · +44 7510 081687
Solar
Solar · Error codes · SolarEdge
2xFSolarEdge · HD-Wave single-phase inverter (SE2200H-SE6000H)

2xF on a SolarEdge HD-Wave single-phase inverter: DC Voltage Too High (surge): The SolarEdge system normally eliminates DC overvoltage errors; if the fault persists check strings

Short answer

On a SolarEdge inverter, 2xF means: DC Voltage Too High (surge): The SolarEdge system normally eliminates DC overvoltage errors; if the fault persists check strings. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: DC Voltage Too High (surge): The SolarEdge system normally eliminates DC overvoltage errors; if the fault persists check strings.

Part involved: PV input over-voltage.

Likely causes:

  • String/optimiser malfunction or connection fault.
  • Commissioning (pairing) issue.

Is it safe?

Switch the inverter off at its isolator and call an engineer.

Does the inverter stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: yes, after string design is corrected.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Call the installer. Do not touch DC cabling.
  • If the code persists, contact the installer. SolarEdge's list says 'OFF/ON to reconnect' for some codes - that means the inverter's own ON/OFF switch; only use it if your installer has shown you how. Never open the inverter or touch DC cables/connectors.

What the engineer will check

  • Measure open-circuit string voltage (cold-weather Voc rise).
  • Check string design against inverter max DC voltage.
  • Check for mixed/incorrect module counts.

Who to ask for: PV installer / system designer.

Certification: Electrician competent in grid-connected PV (BS 7671 Section 712; IET Code of Practice for Grid-connected Solar PV), ideally the original MCS-certified PV installer; brand-approved/trained installer to keep manufacturer warranty.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026