SolarpunkHomes
Sign inCall us · +44 7510 081687
Solar
Solar · Error codes · SolarEdge
18x40SolarEdge · HD-Wave single-phase inverter (SE2200H-SE6000H)

18x40 on a SolarEdge HD-Wave single-phase inverter: AC Freq Too High: The frequency measured on L1 is higher than the thresholds

Short answer

On a SolarEdge inverter, 18x40 means: AC Freq Too High: The frequency measured on L1 is higher than the thresholds. The inverter stops until the fault clears or is reset.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: AC Freq Too High: The frequency measured on L1 is higher than the thresholds.

Part involved: AC grid protection (frequency).

Likely causes:

  • Grid frequency outside G98/G99 limits.
  • Wrong country setting.

Is it safe?

Does the inverter stop?Yes
SeverityFault — clears by itself when the condition goes

The inverter stops until the fault clears or is reset.

Resetting itself: yes - reconnects when frequency is back within limits.

Manual reset: no.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Usually a brief grid disturbance; no action if it clears the same day.
  • Check the solar/battery AC isolator and the consumer-unit breaker/RCD are ON (do not reset a breaker that trips again immediately).
  • If the code persists, contact the installer. SolarEdge's list says 'OFF/ON to reconnect' for some codes - that means the inverter's own ON/OFF switch; only use it if your installer has shown you how. Never open the inverter or touch DC cables/connectors.

What the engineer will check

  • Verify country/grid code (UK G98/G99).
  • Log grid frequency.
  • Check for unstable supply (e.g. generator/backup operation).

Who to ask for: PV installer.

Certification: Usually none (grid-side event). If persistent: installer/electrician to measure supply voltage and check settings; DNO investigates supply voltage (G98/G99 protection settings must not be changed without DNO agreement).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026