CodeMeaningStops?Homeowner check?
7
No heat pump starts exceeded
Not statedYes
10
Outside Sensor Fault
Not statedYes
26
Header Thermistor Fault (used for Cascade Systems)
Not statedYes
33
Flow Thermistor (Indoor) Fault
Not statedYes
44
Return Thermistor Fault
Not statedYes
50
DHW Thermistor Fault
Not statedYes
60
Room Stat 1 Fault
Not statedYes
65
Room Stat 2 Fault
Not statedYes
81
LPB short-circuit/comm Fault
Not statedYes
82
LPB address collision Fault
Not statedYes
83
BSB short circuit Fault
Not statedYes
84
BSB address collision
Not statedYes
100
2 clock time masters Fault
Not statedYes
102
Clock without backup Fault
Not statedYes
106
Source Temp too low
Not statedYes
126
7093 DHW Setpt Fault
Not statedYes
127
Anti-Legionella Temp' Fault
Not statedYes
134
Re-occurring Heat Pump Fault
YesYes
146
Configuration error
Not statedYes
171
Alarm contact 1 active Fault
Not statedYes
366
Room temp sensor Fault
Not statedYes
369
External Fault
Not statedYes
370
Heat Pump fault (outdoor unit) - with F-sub-code
YesYes
370-F0
Heat Pump fault: No outdoor connection fault
YesYes
370-F1
Heat Pump fault: No outdoor connection fault
YesYes
370-F2
Heat Pump fault: Outdoor HX thermistor fault
Not statedYes
370-F3
Heat Pump fault: Heat pump inverter fault
YesYes
370-F4
Heat Pump fault: Outdoor electrical filtering fault
Not statedYes
370-F5
Heat Pump fault: Outdoor discharge thermistor
Not statedYes
370-F6
Heat Pump fault: Compressor thermistor fault
Not statedYes
370-F7
Heat Pump fault: Outdoor intermediate HX thermistor
Not statedYes
370-F8
Heat Pump fault: Outdoor outlet HX thermistor
Not statedYes
370-F9
Heat Pump fault: Heat Pump defrost thermistor fault
Not statedYes
370-F10
Heat Pump fault: Outdoor heatsink thmr fault
Not statedYes
370-F11
Heat Pump fault: outdoor PFC thermistor fault
Not statedYes
370-F12
Heat Pump fault: Outdoor exp valve thmr
Not statedYes
370-F13
Heat Pump fault: Outdoor electrical error
Not statedYes
370-F14
Heat Pump fault: outdoor pressure sensor fault
YesYes
370-F15
Heat Pump fault: Current Trip
YesYes
370-F16
Heat Pump fault: Heat pump compressor fault
YesYes
370-F17
Heat Pump fault: Heat pump fan fault
YesYes
370-F18
Heat Pump fault: Outdoor discharge temp'
YesYes
370-F19
Heat Pump fault: Compressor temperature fault
YesYes
370-F20
Heat Pump fault: Outdoor low pressure
YesYes
370-F21
Heat Pump fault: Outdoor power supply fault
Not statedYes
370-F22
Heat Pump fault: No outdoor connection
YesYes
370-F23
Heat Pump fault: Hydraulic HX temperature
YesYes
370-F24
Heat Pump fault: Primary Circulation Pump
YesYes
370-F25
Heat Pump fault: Evaporator Outlet Thermistor
Not statedYes
370-F26
Heat Pump fault: Outdoor Power Supply
Not statedYes
370-F27
Heat Pump fault: No water flow fault
YesYes
385
Low Mains Voltage Fault
Not statedYes
489
No Cascade Master Fault
Not statedYes
490
No outdoor connection Fault
YesYes
499
No outdoor connection Fault
YesYes
506
Boiler no temp' rise Fault
Not statedYes
516
No outdoor connection Fault
YesYes
C7
Inverter Error
YesYes
E0
No Water Flow, through Outdoor Unit, 10 times in succession
YesYes
E1
Live and Neutral reversed
Not statedYes
E2
No connection Outdoor PCB to User Interface
YesYes
E3
Header Thermistor (T1) Error (for Hybrid/Cascade)
Not statedYes
E4
DHW Cylinder Thermistor (T5) Error
Not statedYes
E5
Outdoor Unit, Air to Refrigerant Heat Exchanger Outlet Thermistor (T3) Error
Not statedYes
E6
Outdoor Sensor within Outdoor Unit (T4) Error
Not statedYes
E8
No Water Flow, through Outdoor Unit
YesYes
E9
Compressor Refrigerant Return Thermistor (Th) Error
Not statedYes
EA
Discharge Thermistor (Tp) Error
Not statedYes
Ed
Outdoor Unit, Return Thermistor (Tw_in) Error
Not statedYes
F1
Inverter Error
YesYes
FC1
Outdoor Unit, Air to Refrigerant Heat Exchanger Outlet Thermistor Error
Not statedYes
H0
No connection Outdoor PCB to Indoor PCB
YesYes
H1
No connection Outdoor PCB to Inverter PCB
YesYes
H2
Plate Heat Exchanger Outlet Refrigerant Thermistor (T2) Error
Not statedYes
H3
Plate Heat Exchanger Inlet Refrigerant Thermistor (T2B) Error
Not statedYes
H4
Inverter High Current (L1E/L11/L12) 3 times within 60mins
YesYes
H6
Fan Error
YesYes
H7
Mains High Voltage or Low Voltage Error
Not statedYes
H8
High Pressure Sensor Error
Not statedYes
H9
Central Heating Zone 2 Thermistor Fault
Not statedYes
HA
Outdoor Unit, Flow Thermistor (Tw_out) Error
Not statedYes
Hb
High Flow/Return Differential, 3 times in succession and Flow Temperature <7C
YesYes
Hd
No connection Master Heat Pump to Slave Heat Pump
Not statedYes
HF
Inverter not matched to Outdoor PCB dip switch setting
YesYes
HH
10 Fan Errors in 2 hours
YesYes
J2E
Inverter High Temperature
YesYes
J3E
Inverter Error
YesYes
J5E
Compressor Error
YesYes
J6E
Inverter Error
YesYes
J11
Inverter High Current
YesYes
J12
Inverter High Current
YesYes
J31
Inverter Error
YesYes
J32
Inverter Error
YesYes
J43
Inverter Error
YesYes
J45
Wrong Fan Motor Fitted
YesYes
J46
Inverter Error
YesYes
J47
Inverter Error
YesYes
J52
Compressor Stall Error
YesYes
J61
Fan Connections Short Circuit
YesYes
J65
Inverter Error
YesYes
L1E
Inverter High Current
YesYes
L2E
Inverter High Temperature
YesYes
L3E
Inverter Error
YesYes
L5E
Compressor Start Error
YesYes
L6E
Inverter Error
YesYes
L11
Inverter High Current
YesYes
L12
Inverter High Current
YesYes
L31
Inverter Error
YesYes
L32
Inverter Error
YesYes
L34
Inverter Error
YesYes
L43
Inverter Error
YesYes
L45
Wrong Fan Fitted
YesYes
L46
Inverter Error
YesYes
L47
Inverter Error
YesYes
L52
Compressor Stall Error
YesYes
L61
Short Circuit to Compressor Terminals
YesYes
L65
Inverter Error
YesYes
LB7
Inverter Error
YesYes
LBC
Inverter Error
YesYes
LBE
High Pressure Switch Operated
YesYes
LC1
Inverter Error
YesYes
LC2
Inverter Error
YesYes
LC3
Inverter Error
YesYes
LC4
Inverter Error
YesYes
LC5
Inverter Error
YesYes
LC6
Inverter Error
YesYes
LC7
Inverter Error
YesYes
LC8
Inverter Error
YesYes
LC9
Inverter High Temperature
YesYes
LCA
Inverter High Current
YesYes
LCB
Inverter Error
YesYes
LCD
Inverter Error
YesYes
LCE
Inverter High Current
YesYes
LED-9B
Circulation pump error
YesYes
LED-10x11
Heat sink temp. error
YesYes
LED-11-forward
Serial communication error (serial forward transfer error) - outdoor unit cannot receive hydraulic unit signal
YesYes
LED-11-reverse
Serial communication error (serial reverse transfer error) - hydraulic unit cannot receive outdoor unit signal
YesYes
LED-23
Combination error
YesYes
LED-32
Outdoor unit PCB model information error
Not statedYes
LED-62
Outdoor unit main PCB error / communication error in outdoor unit
Not statedYes
LED-63
Inverter error
YesYes
LED-65
IPM error
YesYes
LED-71
Discharge temp. sensor error
Not statedYes
LED-72
Compressor temp. sensor error
Not statedYes
LED-73
Heat-exchange middle temp. sensor error / outdoor unit heat-exchange liquid (outlet) temp. sensor error
Not statedYes
LED-74
Outdoor temp. sensor error
Not statedYes
LED-77
Heat sink temp. sensor error
Not statedYes
LED-78
Electric expansion valve sensor error
Not statedYes
LED-79
Water outlet temp. sensor error
Not statedYes
LED-84
Current sensor error
Not statedYes
LED-86-HP-switch
High pressure switch error
YesYes
LED-86-pressure-sensor
Pressure sensor error
Not statedYes
LED-94
Trip detection
YesYes
LED-95
Compressor motor control error (compressor rotor position detection error)
YesYes
LED-97
Outdoor unit fan motor 1 error
YesYes
LED-A1
Discharge temp. error
YesYes
LED-A3
Compressor temp. error
YesYes
LED-A5
Low pressure error
YesYes
LED-AE
Low water flow error (no or insufficient water flow rate)
YesYes
P0
Low Pressure Error
YesYes
P1
High Pressure Switch Operated
YesYes
P3
Overcurrent Protection Error
YesYes
P4
Compressor Discharge Temperature High
YesYes
P5
High Flow/Return Differential
Not statedYes
P21
Low Pressure Sensor Error
Not statedYes
P27
High Pressure Sensor and Low Pressure Sensor Wiring Reversed
Not statedYes
Pd
Condensing Temperature High
Not statedYes
PP
High Flow/Return Differential
Not statedYes